Worked Examples
Apply impact uncertainty — Global Impact Catalyst
Apply impact uncertainty in Global Impact Catalyst using documented measurement assumptions, source-controlled uncertainty models, reproducible calculations, and scientifically defensible reporting boundaries. This guide demonstrates uncertainty propagation, covariance, confidence-interval interpretation, scenario sensitivity, and independent verification without confusing technical model outputs with verified impact or causal findings.
Application: Global Impact Catalyst
Component: Analysis — Uncertainty Models and Scenarios (related: Indicator Registry, Evidence Governance)
Article type: How-to / procedure
Source-reviewed application version: 2.0.0 (commit e75808a0aa272656b1fdbacd2491c30fd6b987dc)
Reviewed analysis module: 1.7.0
Last verified installed uncertainty feature version: Not established; deployment acceptance pending
Evidence status: Source-reviewed method and independent synthetic calculation; scientific and production verification pending
Estimated reading time: 20–25 minutes
Goal
Apply explicit, reproducible uncertainty information to impact observations, derived net indicators, scenarios and comparisons without presenting a declared range as an empirically calibrated confidence interval. The acceptance result is a versioned uncertainty statement that identifies the estimand, units, source data, assumptions, model, dependencies, formula, sensitivity checks, reviewer and claim boundary. Another analyst must be able to calculate the same central estimate and uncertainty budget from the saved inputs.
Use uncertainty to improve decision quality, not to hide weak data, establish causal attribution, or automatically certify an impact claim. A single interval is insufficient when uncertainty from sampling, selection, baseline choice, incomplete measurements and model structure has not been assessed.
Requirements
- Governed context: workspace and initiative identifiers, current revision, indicator definition and direction, unit registry, period, geography and population or activity boundary.
- Source rights: authorized access to observations, source versions, method notes, license, retention and research/privacy approvals.
- Inputs: central estimates, input uncertainty estimates and how those estimates were obtained; identify whether numbers are standard uncertainties, bound widths, confidence limits or subjective scenario choices.
- Dependencies: covariance/correlation or a reasoned independence assumption; identify overlapping samples, shared instruments and common systematic errors.
- Review: a named preparer, separate reviewer when feasible, version-pinned calculation and evidence package; publication control outside the calculation workflow.
- Environment: consult the installed GIC release before following any UI-specific steps. This article documents reviewed source-code methods, not a verified live screen.
1. Define the estimand and boundary
Write one testable question: “What quantity is being estimated, for which population/activity, over which time interval, and with what measurement method?” Separate descriptive uncertainty about measured quantities from counterfactual uncertainty about what would have happened otherwise. For carbon-related work, distinguish recorded gross quantities from upstream emissions, leakage, reversal, baseline assumptions and scientifically demonstrated net removal; a net arithmetic result alone is not proof of a verified removal.
State the time convention, units, coverage, possible dependence between records, exclusions, revision policy and intended comparison before looking at a rank or target. Do not combine tCO₂ and tCO₂e without a disclosed conversion basis, or mix dates and populations merely because the numerical units agree.
2. Review the implemented GIC uncertainty contract
At the pinned v2.0.0 source commit, python/global_impact_analysis.py defines an Analysis v1.7.0 uncertainty model and the methods register_uncertainty_model, get_uncertainty_model, apply_uncertainty, evaluate_scenario and run_sensitivity_analysis. Source review confirms the following types and their mathematical behavior. It does not establish that a matching live WordPress uncertainty UI is deployed.
| Type | Source-reviewed calculation | Scientific interpretation / guard |
|---|---|---|
absolute |
value ± absolute_margin |
Meaning and statistical basis of the margin must be supplied separately |
relative |
value ± |value| × relative_margin_percent/100 |
Relative-only margins collapse to zero at a zero central value; validate that boundary |
bounds |
Explicit lower_bound and upper_bound |
Bounds are stored directly; inspect whether the center lies inside and how bounds were derived |
combined |
value ± √(absolute_margin² + (|value|×relative%/100)²) | Requires justification for RSS and input interpretation; does not model covariance |
Source records also have confidence_level, distribution, assumptions, limitations, source/method references, revision, lifecycle and actor metadata. Supported distribution labels in the reviewed implementation are bounded, normal_assumption, triangular_assumption and unknown. They are annotations; apply_uncertainty does not use them to estimate quantiles or calibrate probability coverage. The default confidence_level=0.95 is a declaration, not statistical proof of 95% coverage.
3. Build an uncertainty budget before calculating
Record each uncertainty source separately. Do not assign a percentage merely to make a report look complete. A practical register distinguishes:
| Contribution | Source of evidence | How it affects the result |
|---|---|---|
| Measurement repeatability | Replicate tests, sampling protocol | Random variation and possible clustering |
| Calibration and instrument drift | Calibration record or equipment certificate | Systematic correction and its uncertainty |
| Sampling and coverage | Population frame, inclusion/exclusion log | Selection bias; may not be captured by standard errors |
| Data processing | Conversions, missingness, revision/cleaning rules | Potential error in transforms and denominators |
| Model and baseline choice | Model comparison, structural assumptions | Alternative structures and counterfactual scenarios |
| Shared effects | Common source, batch, geography or instrument | Non-zero covariance; independence may fail |
For each component, store the input estimate, unit, numerical uncertainty, uncertainty type, distributional basis, derivation, source version/hash, correlation grouping, method version and owner. Missing uncertainty information should be recorded as unknown, not quietly replaced by zero.
4. Work a reproducible synthetic net-indicator example
The companion CSV deliberately contains synthetic quantities in tCO₂e; it is not a field measurement, carbon-credit calculation, policy finding or certification. The arithmetic is a simple net-of-expenses style accounting identity:
N = G − P − T
G = 100 tCO2e, standard uncertainty u(G) = 8 tCO2e
P = 12 tCO2e, standard uncertainty u(P) = 3 tCO2e
T = 8 tCO2e, standard uncertainty u(T) = 2 tCO2e
N = 100 − 12 − 8 = 80 tCO2e
The standard uncertainties are assigned for teaching, not estimated from real replicate measurements. Preserve the sign of each model coefficient. In a full study, the quantities would require evidence of their definitions, system boundary, calibration, sampling, units, revision status and whether they represent independent measurements or shared model assumptions.
5. Propagate standard uncertainty with the full model
For a sufficiently smooth model y = f(x₁,…,xₙ), the first-order variance propagation includes both variance and covariance terms. For the linear example above, write the coefficients c = [+1, −1, −1].
u²(N) = Σ_i c_i² u²(x_i) + 2 Σ_(i<j) c_i c_j Cov(x_i,x_j)
If G, P and T are independent:
u²(N) = 8² + 3² + 2² = 77 (tCO2e)²
u(N) = √77 = 8.774964 tCO2e
Illustrative expanded interval with k=2:
80 ± 2 × 8.774964 = [62.45, 97.55] tCO2e
The result 80 ± 8.77 tCO₂e expresses a central value and illustrative combined standard uncertainty. The interval with k=2 is only an illustrative expanded interval: it is not automatically a validated 95% confidence interval. Statistical coverage requires an adequately justified distributional model, uncertainty estimates and appropriate coverage factor. See NIST TN 1297 and JCGM guidance.
6. Challenge dependence and common-mode errors
Suppose gross quantity G and processing quantity P share a measurement or model. Their covariance affects the variance of G − P − T. Under a stated hypothetical correlation ρ(G,P):
u²(N) = 77 − 2 × 8 × 3 × ρ(G,P)
ρ = +0.4 ⇒ u²(N)=57.8 ⇒ u(N)=7.60 tCO2e
ρ = 0 ⇒ u²(N)=77.0 ⇒ u(N)=8.77 tCO2e
ρ = −0.4 ⇒ u²(N)=96.2 ⇒ u(N)=9.81 tCO2e
These are sensitivity cases, not estimated correlations. If the correlation is unknown, show a defensible range or treat it as an unresolved risk. RSS without covariance is not automatically conservative. Systematic bias and uncertain model structure may not be captured even after including known covariance.
7. Separate uncertainty from scenario and sensitivity ranges
Measurement uncertainty describes uncertainty associated with an estimated quantity under a measurement model. A scenario describes conditional output under specified changes in assumptions. A sensitivity analysis shows how output responds to chosen perturbations. These concepts are not interchangeable.
GIC’s evaluate_scenario can attach the result of apply_uncertainty to each scenario point. Its run_sensitivity_analysis evaluates low, baseline and high parameter values and reports mathematical responsiveness. Neither operation independently measures uncertainty in an actual population nor transforms a scenario into a forecast. Keep scenario axes, physical units, assumption sources, period definition and model-revision IDs visible.
8. Compare groups without overstating a ranking
Consider a second wholly synthetic indicator of 74 tCO₂e with assigned standard uncertainty 7 tCO₂e. Under independent errors between cases, the estimated difference is 80 − 74 = 6 and the standard uncertainty is √(77 + 49) = 11.22 tCO₂e. The illustrative k=2 range for the difference is [−16.45, 28.45] tCO₂e.
This interval crosses zero. The data are insufficient for a firm direction-of-difference statement under these assumptions. Moreover, the two cases might share data sources, periods or model errors, invalidating independence. A responsible comparison should include the common covariance, matched time/units and an explicit policy governing missing observations and populations. Never infer superior impact, significance or attribution from the point estimates alone.
9. Reproduce the calculation independently
Use the provided read-only Python 3 script with the exact synthetic CSV. The script checks the expected component inventory, unit, sign, finite values, synthetic designation and recorded uncertainty basis; it then calculates the central value, standard uncertainty, covariance sensitivities, comparison gap and seeded illustrative Monte Carlo distribution.
python3 uncertainty_workbench.py synthetic_impact_uncertainty_2026.csv \
--output synthetic_results.json
python3 -m pytest -q
The Monte Carlo module uses 30,000 independent Gaussian draws with fixed seed 20261126; it should approximately reproduce the analytical mean and standard uncertainty under the same assumptions. It does not test the accuracy of the assumptions themselves. The simple code should not be substituted for a validated production scientific package.
10. Translate a vetted uncertainty budget into GIC
After scientific review, select the uncertainty representation that matches the evidence. For a source-reviewed API/Python integration, the exposed repository method is register_uncertainty_model(model, workspace_id=…, expected_revision=…, actor=…). The companion apply_uncertainty(model_id, value) computes a displayed range; a reviewed scenario can reference an uncertainty model when evaluated. The following object is illustrative structured input, not a confirmed WordPress form or a tested production request:
{
"name": "Synthetic net indicator — illustrative standard margin",
"uncertainty_type": "absolute",
"absolute_margin": 8.774964387392123,
"confidence_level": 0.95,
"distribution": "unknown",
"lifecycle_status": "draft",
"assumptions": [
"Input uncertainties are illustrative 1-sigma estimates",
"G, P and T assumed independent for this baseline"
],
"limitations": [
"The 0.95 field is metadata, not calibrated coverage",
"No model-bias, sampling or attribution validation"
]
}
Critical distinction: this absolute_margin represents a one-standard-uncertainty quantity; GIC would return value ± 8.775 for this model, not automatically value ± 17.55 or a 95% coverage interval. If a separately justified expanded interval is desired, record the coverage factor and interval derivation explicitly. Do not silently change margin semantics. A production implementation should preserve the underlying scientific uncertainty budget in evidence metadata, not only the display margin.
11. Verify the GIC four-type calculations
Perform exact numerical comparisons on synthetic fixtures before release:
| GIC model | Test input | Expected source-code behavior |
|---|---|---|
| Absolute | value 80; margin 6 | [74, 86] |
| Relative | value 80; 10% | [72, 88] |
| Explicit bounds | value 80; lower 65; upper 95 | [65, 95]; verify the center and units separately |
| Combined RSS | value 80; absolute 6; relative 10% | 80 ± 10, i.e. [70, 90] |
| Relative at zero | value 0; 10% | [0, 0] by implementation; a scientific red flag when background uncertainty remains |
For combined, the calculation is √(6² + 8²) = 10. Do not automatically label these two inputs independent one-standard uncertainties without separate evidence. Compare values to the pinned source, and rerun against the installed release before marking production verification passed.
12. Address missingness, thresholds and asymmetry
Reject or quarantine unavailable values and absent uncertainty bases; do not interpret omitted uncertainties as zero. For a partial record, report the scope and excluded observations. If the model has nonnegative support, skewness, detection limits or capped fractions, symmetric normal approximations can produce impossible lower bounds. Do not automatically truncate these bounds without documenting the resulting bias; consider an appropriate transformed model, distributions or Monte Carlo propagation with the correct support.
For ratios, small denominators create nonlinear uncertainty. A delta method may fail near zero. For time-series or site comparisons, shared observations and autocorrelation matter. Record the policy and use independent validation appropriate to the actual study design.
13. Assess source quality and uncertainty coverage
For every source, record its stable ID and version; retrieve the source locator; check measurement protocol, sampling design, calibration, uncertainty statement, rights, revision history, and consistency with the metric’s population/time/geography. If a paper reports a 95% confidence interval, do not insert its half-width as a one-standard-deviation margin without accounting for its method, degrees of freedom, covariance and any transformation.
Attach alternative model runs for plausible baseline choices, data exclusions, correlation assumptions and method versions. Make explicit which uncertainties are quantified, only bounded, or completely unknown. A stable code path does not compensate for biased evidence.
14. Maintain governance, privacy and publication separation
Preserve the workspace, initiative, indicator, input revisions, method definitions and evidence links. Use restricted data only within its approved scope; public outputs should exclude personal records, unnecessary geospatial precision, API keys, private reviewer comments and confidential source excerpts. A calculation that finishes successfully must never change the subject’s editorial state from draft to approved.
The reviewed GIC publication guidance separately requires matching subject hashes, approval, quality thresholds and no unresolved corrections. A modeled interval is not an assurance opinion, certification, causal finding or authorized public release. Record the reviewer’s disposition and any remaining risks independently from the analysis run.
15. Report a defensible uncertainty statement
Use a compact, auditable result record that includes the following fields: central result and units; input values and source versions; uncertainty budget with type and derivation; covariance assumptions; method and calculation version; interval formula and coverage interpretation; material exclusions and bias risks; sensitivity results; dataset rights; reviewer and release status.
Illustrative wording: “A synthetic net indicator was calculated as 80 tCO₂e, with combined standard uncertainty 8.77 tCO₂e under independent illustrative input errors. A k=2 interval is 62.45–97.55 tCO₂e; its coverage is not empirically calibrated. Correlation and model/baseline uncertainty remain unresolved. The result is not a verified carbon-removal claim.”
Procedure
- Define: identify the outcome, units, population and analysis boundary; distinguish descriptive measurement from causal inference.
- Gather: retrieve authorized, versioned sources, records, methods, approvals and existing uncertainty estimates.
- Budget: classify measurement, sampling, model, bias, missingness and covariance; reject unlabelled percentages.
- Calculate: use an explicit equation and independent implementation; report central estimate, combined uncertainty and the meaning of any interval.
- Stress-test: vary correlations, model choices, missing-data policies and relevant input bounds; independently compare with a reference calculation.
- Record: retain source hashes, method version, formulas, validation failures and reviewer disposition.
- Package: select a GIC source-supported uncertainty record or scenario annotation where appropriate; confirm the installed release before UI/API execution.
- Publish separately: obtain authorization and review; do not promote a completed computation into an approved claim.
Troubleshooting
Use the earliest failing step in the sequence input → units → method → uncertainty budget → covariance → calculated interval → display → disclosure. Preserve the original artifact and audit trail before making a correction.
| Symptom | Likely cause | Action and acceptance criterion |
|---|---|---|
| Interval is too narrow or zero | Relative-only margin at value zero; missing uncertainty contributions | Add evidence-based absolute uncertainty or mark unknown; rerun independent budget |
| Two tools disagree about “95%” | One uses standard error, another expanded or percentile range | Reconcile interval type, assumptions, k, sample design and calibration |
| Small margins despite shared sensors | Unmodeled covariance or systematic calibration error | Inspect common-mode sources; test positive/negative plausible correlations |
| Range extends below impossible physical bound | Symmetric approximation inappropriate | Choose defensible bounded or transformed model; document effect |
| Scenario displayed as forecast | A conditional path mislabelled as predictive evidence | Correct title and limitations; block publication until reviewer approves |
| Unexpected unit or period mismatch | Stale definition, source vintage, conversion or time window | Verify exact unit, method, observation and source version IDs |
| Published result lacks caveat | Draft or approval bypass; report omitted source limitations | Contain public output; preserve logs; restore approved snapshot after review |
| Uncertainty labeled verified because metadata=0.95 | Configured label mistaken for calibrated coverage | Remove unsupported confidence assertion; require validation evidence |
For privacy/authorization failures, suspend affected public surfaces, preserve nonsecret evidence, notify the responsible owner and follow the applicable incident policy. Avoid diagnostic exports containing identifiable people.
Verification
Mark scientific and operational acceptance PASS only when the following are independently substantiated:
- Reproduction: the raw inputs and exact formula reproduce 80 and 8.774964 tCO₂e in the synthetic test; a changed sign fails the consistency check.
- Numerical consistency: the 30,000-draw Gaussian simulation approximately agrees with analytic standard uncertainty under the same independence assumptions.
- Dependence sensitivity: ρ=+0.4 and ρ=−0.4 yield appropriately different standard uncertainties, with covariance signs checked.
- Comparison: the synthetic A–B difference interval crosses zero, so a directional ranking claim is withheld.
- Evidence: no record is missing its source ID, vintage, uncertainty basis, limitations or rights designation in a real review.
- GIC parity: the installed version reproduces source-reviewed absolute, relative, bounds and combined cases, including zero and invalid-input cases.
- Privacy: tenant permissions, restricted source redaction and audit history are verified on a permitted staging account.
- Publication: a calculation creates no implicit approval; reviewers inspect the exact subject snapshot and unresolved corrections.
The provided offline fixture verifies only the local demonstration; it is not live-product, scientific field, coverage-calibration or independent-approval acceptance.
16. Negative tests and staging acceptance
At minimum, stage negative cases for missing standard uncertainty, negative uncertainty, NaN/Infinity, duplicate input, wrong unit or sign, |ρ| > 1, wrong method version, stale data, mixed populations and intervals reported with unsupported coverage. Include cross-tenant access, unauthorized exports, draft-publish attempts, withdrawn records and missing audit provenance.
Run tests on the deployed artifact in an isolated environment; capture build hash, WordPress/plugin version, actual run date, tester identity, expected and observed results and rollback pathway. The supplied staging matrix is NOT_RUN until that evidence exists.
17. Known limitations
- GIC’s documented combined-margin calculation is not a generic propagation engine for arbitrary nonlinear functions or correlated inputs; use separately validated analysis where required.
- GIC’s
confidence_leveland distribution labels do not establish coverage, nor does a scenario run certify predictive skill. - The companion code assumes three synthetic component roles with fixed signs; it is not a general instrument or emissions verifier.
- The independent Gaussian Monte Carlo example is informative only under the stipulated distribution, covariance and independence conditions.
- Coverage, systematic bias, residual baseline uncertainty, confounding, omitted variables, leakage and attribution are not resolved by a standard-error calculation.
- Installed product version and interface behavior have not been independently verified.
18. References and reviewed source evidence
- NIST TN 1297 — Combined Standard Uncertainty. Measurement equation and RSS/covariance treatment.
- NIST TN 1297 — Expanded Uncertainty. Coverage-factor interpretation.
- NIST TN 1297 — Reporting Uncertainty. Reporting of uncertainty and method.
- BIPM/JCGM 101:2008 — Monte Carlo propagation. Distribution-based numerical propagation.
- GIC source:
python/global_impact_analysis.py, pinned commit. Actual registered uncertainty methods, scenario evaluation and sensitivity functions. - GIC source: scenario and uncertainty governance. Claim and interpretation boundaries.
- GIC source: claim governance. Descriptive versus contribution/causal claims.
- GIC source: Indicator Registry. Units, methods and versioned indicator definitions.
- GIC source: v2.0.0 release documentation. Source-reviewed release reference; not deployment proof.
Editorial and technical boundary: The article and synthetic companion validator were prepared for review, not independently approved or deployed. Revalidate against the installed release and the actual scientific study before reliance or public claims.
