Worked Examples
Validate scientifically impact uncertainty — Global Impact Catalyst
Scientifically validate impact-uncertainty calculations in Global Impact Catalyst through documented measurement models, reproducible uncertainty budgets, covariance sensitivity, and appropriately interpreted confidence or scenario ranges. This guide distinguishes source-reviewed GIC arithmetic from independent scientific coverage validation, using a synthetic emissions-style calculation and tests for unsupported comparisons or publication claims.
Application: Global Impact Catalyst
Component: Analysis — Uncertainty Models and Scenarios (related: Indicator Registry, Evidence and Claim Governance)
Article type: Scientific validation
Source-reviewed application version: 2.0.0 (commit e75808a0aa272656b1fdbacd2491c30fd6b987dc)
Reviewed Analysis module version: 1.7.0
Last verified installed uncertainty-feature version: Not established; staging and production acceptance pending
Evidence status: Source-reviewed implementation and offline synthetic calculation; empirical coverage and independent review pending
Estimated reading time: 21–26 minutes
Goal
Determine whether an impact-uncertainty result is numerically reproducible, methodologically appropriate, statistically interpretable and responsibly reportable. A valid analysis must answer a specified scientific question, recreate all calculations from source-controlled inputs, disclose material sources of uncertainty, challenge dependence assumptions, and separate the recorded estimate from claims of impact, comparison or causal attribution.
The primary acceptance criterion is not merely that a model returns an interval: reported uncertainty and any stated confidence or scenario range must reflect available evidence and be correctly labeled. Where measurement, dependence or model-form evidence is absent, label that uncertainty not assessed, not zero.
Requirements
- Study protocol: estimand, system boundary, eligibility criteria, observation dates, geography, population/activity, unit, intended claim, risk classification and version.
- Traceable evidence: raw observations or justified modeled inputs; source identifiers, licenses, revision timestamps and checksums; exclusions and quality flags.
- Uncertainty budget: components, numerical standard uncertainties or documented bounds, basis of estimates (Type A or Type B), units, distributions, sensitivities and dependence.
- Comparability: for a difference or rank, match indicator definitions, units, periods, denominator, method, sampling coverage and common-error structure.
- Governance: permitted workspace, actor role, evidence rights, independent reviewer, versioned calculations and publication approval distinct from computation.
- Reproduction tools: the companion synthetic CSV and Python diagnostic script; not a live GIC API or a replacement for a metrologist/statistician.
Study design and definitions
1. Define the study design and measurement boundary.
Define the measurand (the quantity intended to be measured) and the estimand (the target quantity for the analysis) in unambiguous operational language. Record the analysis unit, time window, sampling frame, which observations are independent, and whether results describe a finite set of recorded cases or a larger population. The planned claim determines the required design: a descriptive estimate, progress-to-target, between-site difference and causal attribution have fundamentally different evidential requirements.
For the synthetic example, the analysis quantity is N = G − P − T, an illustrative net tCO₂e indicator formed from a hypothetical gross quantity and two hypothetical process-related quantities. It does not establish a carbon-removal pathway, additionality, permanence, lifecycle completeness, or eligibility for certification. Excluded components and their unquantified uncertainty must be reported before using the result outside the teaching fixture.
2. Implemented GIC functionality and its scientific boundary
Reviewing python/global_impact_analysis.py and python/global_impact_service.py at the pinned source commit establishes a v1.7.0 Analysis repository with register_uncertainty_model, get_uncertainty_model, apply_uncertainty, evaluate_scenario and run_sensitivity_analysis. This is source evidence, not proof that a corresponding WordPress UI or authorized public endpoint is live.
| Uncertainty type | Reviewed calculation | Required independent check |
|---|---|---|
absolute |
value ± absolute_margin |
Origin, units and statistical meaning of margin |
relative |
value ± |value| × relative_margin_percent / 100 |
Scale dependence, near-zero values and instrument floor |
bounds |
Saved lower and upper endpoints | Physical plausibility, center inclusion and derivation |
combined |
value ± sqrt(absolute_margin² + relative_margin²), where relative margin is first converted to absolute at the value |
No double-counting; covariance assumption; uncertainty components are compatible |
The reviewed implementation checks supported types, finite nonnegative margins, ordered bounds and a declared confidence_level in (0, 1]. Distribution labels (bounded, normal_assumption, triangular_assumption, unknown) are metadata: apply_uncertainty does not derive statistical quantiles from them. It also does not automatically propagate covariance through a two-site comparison. Its bounds validator checks lower ≤ upper but does not independently establish that the central estimate belongs to that range. These are scientific review checks, not claims of a software bug in a verified deployment.
3. Uncertainty taxonomy and evidence requirements
| Source | Typical supporting record | Validation question |
|---|---|---|
| Repeatability / sampling variation (Type A) | Replicates, sample count, design, cluster IDs | Are variability and dependence estimated from an appropriate sample? |
| Calibration / measurement bias (often Type B) | Calibration chain, instrument drift, reference method | Are corrections and their uncertainties represented? |
| Conversions and denominators | Units, population factors, conversion revision | Are transformed measurements and uncertainty in factors included? |
| Missingness and selection | Inclusion/exclusion protocol, missing-data counts | Can selection shift the estimate rather than only widen a random interval? |
| Shared inputs / common-mode errors | Covariance matrix, shared-device or model lineage | Does root-sum-square independence understate or overstate uncertainty? |
| Model choice and counterfactual assumptions | Alternative model structures, pre-specified scenarios | Are model-form effects disclosed separately from measurement standard error? |
Document whether a numerical entry is a standard uncertainty, variance, expanded uncertainty, bound half-width, standard error, interquartile range or expert judgment. These cannot be interchanged by changing a metadata label. Confidence cannot be inferred from a source’s prestige or from the presence of a source citation alone.
Method and evidence
4. Reproduce the synthetic baseline calculation.
The companion dataset records the following invented values and illustrative one-standard-uncertainty inputs, all in tCO₂e:
| Component | Coefficient | Value | Illustrative standard uncertainty |
|---|---|---|---|
Gross (G) |
+1 | 100 | 8 |
Processing (P) |
−1 | 12 | 3 |
Transport (T) |
−1 | 8 | 2 |
N = G − P − T = 100 − 12 − 8 = 80 tCO2e
For independent inputs:
u²(N) = (1×8)² + (−1×3)² + (−1×2)² = 77 (tCO2e)²
u(N) = sqrt(77) = 8.774964 tCO2e
Illustrative k=2 expanded range:
80 ± 2×8.774964 = [62.4501, 97.5499] tCO2e
A second analyst should calculate the same arithmetic without relying on a platform-rendered display. This proves reproducibility under supplied assumptions, not empirical accuracy or a statistically validated 95% interval. The input uncertainties are invented rather than derived from measurements.
5. Propagate covariance and test independence
For a linear result N = Σcᵢxᵢ, the full variance includes off-diagonal covariance terms. The JCGM 100:2008 GUM and NIST combined-uncertainty guidance require covariance to be considered when inputs are correlated:
u²(N) = Σ(cᵢ² uᵢ²) + 2 Σ(i<j) cᵢ cⱼ Cov(xᵢ,xⱼ)
Cov(G,P) = ρ × u(G) × u(P), with other covariances assumed zero
u²(N) = 77 − 48ρ
| Illustrative ρ(G,P) | Variance | Standard uncertainty | Interpretation |
|---|---|---|---|
| −0.4 | 96.2 | 9.8082 tCO₂e | Net uncertainty increases |
| 0 | 77.0 | 8.7750 tCO₂e | Independence benchmark only |
| +0.4 | 57.8 | 7.6026 tCO₂e | Net uncertainty decreases due to subtraction |
Correlations are hypotheses for sensitivity testing, not measured parameters. A reviewer must investigate shared instruments, calibration standards, process assumptions, sampled populations and time-dependent effects. If covariance cannot be estimated, report the missing knowledge and the consequences of plausible alternatives rather than asserting independence as fact.
6. Validate distributions, nonlinear effects and Monte Carlo
Under a synthetic independent Gaussian input assumption, the reproducible companion Monte Carlo (30,000 draws; fixed seed 20261126) yields mean approximately 80.05 tCO₂e, standard deviation 8.78 tCO₂e, and 2.5th–97.5th percentiles approximately 62.79–97.30 tCO₂e. The proximity to the analytic result is expected for this linear-Gaussian demonstration. It is not evidence that actual observations are Gaussian or independent.
Use distributional propagation as described in JCGM 101:2008 when the response is nonlinear, discontinuous, skewed, truncated, close to physical limits, or otherwise unsuitable for symmetric first-order approximations. For an empirical study, validate input distributions, dependency structure, random seed, draw count, convergence, output tails and sensitivity to alternate priors or model specifications. A Monte Carlo result generated from invented assumptions cannot validate those assumptions.
7. Distinguish reported confidence from demonstrated coverage
The confidence_level field and a normal_assumption label on a GIC uncertainty model are declarations. A reported 0.95 does not, by itself, establish that 95% of repeated equivalent studies would contain the true value or that a chosen interval has 95% coverage. NIST expanded-uncertainty guidance discusses coverage factors, while NIST reporting guidance requires an explicit description of the uncertainty statement and assumptions.
For a real study, verify the uncertainty estimation design, distributional adequacy, effective degrees of freedom when applicable, intended interpretation, coverage-factor choice and any back-testing or reference comparisons. Avoid calling a generic k=2 symmetric band a validated 95% confidence interval. If actual coverage is not demonstrated, publish illustrative expanded range or assumption-dependent scenario interval with a clear statement of what remains unverified.
8. Compare two uncertain results without ranking by point estimate
Define a synthetic second-site benchmark of 74 tCO2e with standard uncertainty 7 tCO2e. Under an assumed independent-site model:
Difference D = 80 − 74 = 6 tCO2e
u(D) = sqrt(8.774964² + 7²) = sqrt(126) = 11.224972 tCO2e
Illustrative k=2 range for D = 6 ± 22.449944
D ∈ [−16.4499, 28.4499] tCO2e
The range includes zero. The numerical ordering (80 versus 74) therefore does not justify an unqualified claim that one site performed better. A reviewer must also check common systematic errors, whether both sites use the same period and population definition, shared source revisions, and possible site-level confounding. A narrower interval from silently omitting uncertainty is not stronger scientific evidence.
9. Test missing data, quality and source revisions
Construct a manifest linking each raw observation and derived result to the exact source revision, sampling/measurement method, preprocessing script, unit registry, exclusion decision and reviewer. Revisions to calibration or baseline data must trigger a new computation and a new traceable result version; historical reports should not silently rewrite their evidence. Missing records must have visible flags and justified handling.
Perform a leave-one-component-out test only as a diagnostic of model reliance; omission changes the modeled quantity and must never be presented as a valid revised estimate without scientific justification. Re-estimate results under plausible alternative treatment of missingness and a physically defensible range for unmeasured components. If omissions are potentially systematic, do not assume they merely add random variance.
10. Challenge scenario and model-form uncertainty
Separate input measurement uncertainty from uncertainty about the structural model, baseline, policy pathway, intervention timing and counterfactual. Review competing methods and the scientific reasons to include or exclude them. For a scenario, record its parameters, horizon, assumptions, distribution or bound choice, and whether the path is conditional rather than predictive.
GIC’s source-reviewed evaluate_scenario can annotate each scenario point with an uncertainty model, and run_sensitivity_analysis can measure how changing declared parameters changes the scenario output. Mathematical sensitivity is not evidence of real-world causal influence. Neither function alone establishes an uncertainty distribution for an arbitrary between-site comparison or combines measurement uncertainty with omitted model-form uncertainty.
Validation
11. Scientific acceptance gates.
| Gate | Pass criterion | Failure / escalation |
|---|---|---|
| SC-IU-SCI-01 — Measurand | Target quantity, scope, units and period documented | Hold: ambiguous quantity or incompatible measurement boundary |
| SC-IU-SCI-02 — Traceability | All input values and revisions recoverable | Hold: missing provenance or license |
| SC-IU-SCI-03 — Budget | All material components and their uncertainty basis disclosed | Hold: invented precision or unqualified zero uncertainty |
| SC-IU-SCI-04 — Reproduction | Independent calculator recreates value and spread within predeclared tolerance | Investigate unit/sign/formula/rounding differences |
| SC-IU-SCI-05 — Dependence | Covariance assessed or uncertainty sensitivity disclosed | Hold: unsupported independence premise |
| SC-IU-SCI-06 — Coverage | Interval type and evidential interpretation justified | Remove unsupported “95% verified” language |
| SC-IU-SCI-07 — Comparison | Difference uncertainty, shared error and comparability checked | Block unsupported directional ranking |
| SC-IU-SCI-08 — Governance | Reviewer, permission, corrections and release decision evidenced | Do not infer approval from save/run |
These identifiers are article-defined acceptance cases, not verified preexisting GIC test IDs or active workflow controls. Record NOT_RUN for every staging or scientific-review gate lacking direct evidence.
Verification
12. Independent numerical checks.
- Read the unmodified CSV and confirm exactly three named components, expected coefficients, a common tCO₂e unit and a synthetic source declaration.
- Recompute
N=80, variance77and combined standard uncertaintysqrt(77)without using the reported result as an input. - Repeat the calculation with
ρ=±0.4; confirm covariance changes uncertainty with the correct sign. - Repeat 30,000 seeded Monte Carlo draws and inspect their mean, spread, quantiles and convergence to the analytic linear-Gaussian reference.
- Compute the two-site difference and hold directional assertions while the illustrative interval contains zero.
- Reject altered signs, units, missing values, nonfinite numbers, negative standard uncertainties and invalid correlation coefficients.
- Audit published wording: central estimate, standard versus expanded uncertainty, coverage assumptions, source vintage, limitations, approval status and source access restrictions.
Passing these offline checks validates the companion calculation. It does not validate GIC deployment, field measurement accuracy, statistical coverage, causal impact or publication authorization.
Troubleshooting
| Symptom | Likely cause | Diagnostic / recovery |
|---|---|---|
| Uncertainty unexpectedly tiny or zero | Relative-only margin at zero; missing calibration or unmeasured inputs | Identify components omitted from budget; label unknown and review lower bound on uncertainty |
| Independent result differs from GIC output | Standard-versus-expanded value, double-counted relative component, wrong unit or wrong sign | Pin inputs and compare each intermediate quantity against the reviewed formula |
| Bounds exclude central estimate | Manual bound entry or mismatched revisions | Flag scientific incoherence; recover original evidence and recompute before approval |
| Claim reports “95%” without support | Metadata confidence_level=0.95 treated as calibration |
Correct wording and require empirical/distributional support |
| Site ranking flips under assumptions | Overlap, covariance, source/model uncertainty or variable case definitions | Report range and sensitivity; withdraw unqualified ranking |
| Simulation disagrees with analytic approximation | Nonlinear function, non-Gaussian inputs, correlated draws, or code error | Inspect raw draws and assumptions; use an independent implementation |
| Result appears publicly without review | Misconfigured permission or publication gate | Contain public exposure, preserve nonsecret audit evidence, escalate to owner |
14. Negative tests and counterexamples
Scientific falsification should include at least these designed counterexamples: wrong sign for a subtracted component; kgCO2e treated as tCO2e without conversion; NaN/Infinity and negative standard uncertainty; missing or duplicate components; |ρ| above 1; missing covariance evidence; center outside purported bounds; zero estimate with a relative-only margin; unrealistically precise interval after excluding a common calibration error; two-site rank described as certain despite a difference interval crossing zero; and a “verified 95%” statement generated solely from a confidence metadata field.
For workflow assurance, add stale-revision writes, unauthorized tenant access, private-source export, lack of licensed reuse, withdrawn-source reuse, audit logging gaps, and draft-to-published transitions without authorization. Run only against synthetic or permitted staging fixtures; do not copy restricted case data into public issue trackers.
15. Reproducibility and audit packet
The reviewer packet should contain a manifest with canonical record IDs, source/vintage, checksum, observation and method versions, exact formula, software commit, random seed, dependency/covariance model, tolerance, exclusion log, raw and derived units, test evidence, reviewer identity, approval state, and immutable result hash. Clearly mark which parts are synthetic and which were independently observed.
To reproduce the shipped example locally, run the following commands from the package directory:
python3 uncertainty_workbench.py synthetic_impact_uncertainty_2026.csv --output independently_reproduced.json
python3 scientific_validation.py synthetic_impact_uncertainty_2026.csv --output scientific_gate_report.json
python3 -m pytest -q test_uncertainty_workbench.py test_scientific_validation.py test_article_structure.py
The scientific gate report deliberately distinguishes locally passed arithmetic/structure checks from items that require field data, independent review or an installed-product test.
Reporting boundary
16. Confidentiality and independent scientific review.
Reports must distinguish central estimate, standard uncertainty, expanded interval, scenario range, and validated coverage. Do not turn a simulation quantile into a confidence statement without a defensible probability model. If the evidence concerns people, maintain participant consent, privacy classification, data minimization and access-rights controls; only approved aggregate findings and nonsecret evidence references may be exposed publicly.
Disclose the source of uncertainty inputs, shared errors, model limitations, possible confounding, conflicts of interest and reviewer decisions. A reproducible computation does not certify source data, causal effects, additionality, permanence, public benefit or policy success. Escalate material scientific disagreement to an independent reviewer before any high-stakes publication.
17. Deployment and independent-review status
The implementation references here are tied to a known source-reviewed v2.0.0 commit, while the Analysis module advertises v1.7.0. These are not verified installed release identifiers. To establish deployed acceptance, an authorized tester must record the actual installed build hash, application/service entry point, role and tenant, functional tests for each uncertainty type, versioned audit events, approved-publication behavior, observed expected/actual values, independent scientific sign-off and rollback evidence.
Do not change a pending staging row to PASS because the standalone Python fixture passed. Do not represent a completed source-code review as independent scientific assessment, and do not infer a published claim from a successful save.
18. References and reviewed source evidence
- JCGM 100:2008 — Guide to expression of uncertainty in measurement. Measurement models, correlated inputs and uncertainty budgets.
- JCGM 101:2008 — Monte Carlo propagation. Propagation of assumed input distributions through mathematical models.
- NIST TN 1297 — Combined Standard Uncertainty. Standard uncertainties and covariance-aware propagation.
- NIST TN 1297 — Expanded Uncertainty. Coverage-factor interpretation and limitations.
- NIST TN 1297 — Reporting Uncertainty. Complete and transparent statements of measurement uncertainty.
- Global Impact Catalyst — python/global_impact_analysis.py, pinned v2.0.0 commit. Uncertainty type validation, interval arithmetic and scenario sensitivity.
- Global Impact Catalyst — python/global_impact_service.py. Service delegation for uncertainty models and analysis.
- GIC — Scenario and Uncertainty Governance. Intended limitation of model annotations.
- GIC — Indicator Registry. Versioned indicator, unit and method definitions.
- GIC — Claim Governance. Distinction between descriptions, contribution claims and causation.
- GIC — v2.0.0 release document. Version scope, not proof of production deployment.
Verification caveat: This article and its companion synthetic tool are prepared for editorial and technical review. Real scientific methods, empirical calibration, independent reviewer acceptance and deployed software behavior remain to be established.
