Worked Examples

Apply figure insertion and captions — Reporting Studio

Embed graphs with units, explanatory captions and source attribution.

ProductSustainable Catalyst Platform CoreUpdatedNovember 16, 2026Reading time15 minutes

Application: Reporting Studio
Related applications: Research / Workspace / Library / Citation Studio / Workbench / Research Lab / Site Intelligence / Research Hub / Platform Core
Classification: Practical Guides / Figure Insertion and Captions
Audience: Researchers, scientific authors, editors, analysts, reviewers, and publication administrators
Technical level: Intermediate
Estimated reading time: 15–19 minutes, excluding figure preparation, source inspection, and export testing
Primary outputs: Version-bound figure reference, accurate image or vector rendering, numbered caption, source attribution, accessible equivalent, and verification record
Primary acceptance: Every published figure must visually and numerically match an authorized source artifact and its exact revision, with an interpretable caption and traceable provenance.

1. Purpose and scientific principle

Figures are scientific evidence displays, not decorative illustrations. An inserted chart can mislead if its underlying data, units, scales, transformation, uncertainty, or source identity is unclear—even if the image looks polished.

This workflow answers five questions: What does the figure show? Which approved data and method produced it? Are the quantitative encodings accurate? Can readers understand it independently of the surrounding prose? Does the saved and exported report still reference the exact reviewed artifact?

Core principle: A figure’s visible marks, caption, numerical values, method, and source provenance must describe the same research object and revision.

2. Identify the report and insertion context

  1. Confirm organization, Workspace project, research output, document owner, and intended audience.
  2. Open the correct report revision and identify the section where the figure supports a finding.
  3. Determine whether the report is a draft, under review, accepted, or already public.
  4. Establish whether the figure is original, derived from another source, adapted with permission, or reproduced from published material.
  5. Check source-access rights, disclosure restrictions, and the publication scope before insertion.

A figure suitable for a private Workspace draft may not be suitable for public Research Hub release. A successful editor insertion does not constitute rights clearance or publication approval.

3. Choose a figure that answers a scientific question

Table 1. Scientific figures and their intended uses
Figure Typical question Essential checks
Scatter plot How do two measured variables vary together? Units, sample size, outliers, fitting assumptions
Time series How does a variable change over time? Time origin, sampling interval, missing data, uncertainty
Bar or point comparison How do groups or estimates differ? Baselines, denominators, interval definitions, grouping
Distribution plot How are observations distributed? Sample sizes, binning or summary statistics
Uncertainty plot How precise or variable is an estimate? Whether bars represent SD, SE, CI, or another interval
Geospatial map Where does a pattern occur? Projection, spatial scale, data date, coverage, legend
Heat map How do values differ across a matrix or space? Color scale, limits, missing cells, underlying values
Method diagram How was the investigation or workflow conducted? Correct sequence, defined relationships, version
3D model or simulation How does a system vary in three dimensions? Axis definitions, viewpoint, geometry, accessible alternatives

Do not select a 3D plot when a 2D comparison would communicate the evidence more clearly. Avoid decorative charts that do not contribute directly to the report’s research question or interpretation.

4. Verify the source artifact before insertion

Record and inspect the authoritative figure source rather than selecting a similarly named image from local downloads.

Table 2. Minimum figure manifest
Field Required meaning
Figure ID Stable identity of the logical scientific figure
Figure revision Exact render or specification version selected
Data identity Dataset identifier, snapshot, and time coverage
Analysis identity Notebook, script, model, run, or method revision
Artifact identity Immutable object reference and checksum where supported
Units and scales Variable definitions, axis transformations, and boundaries
Uncertainty Applicable error definitions and estimation method
Rights Originator, license, attribution, and permitted publication
Status Draft, verified, reviewed, approved, or public, according to actual workflow

Do not assume a green status indicator or a hash alone establishes scientific validity. Verify the data-to-mark relationship and the analytic assumptions separately.

5. Prepare the figure for publication

Review the plot in the original renderer or authoritative saved artifact:

  • Use descriptive variable names and consistent, explicit units.
  • Check the displayed minimum, maximum, and tick intervals on each axis.
  • Make log scales, standardization, normalization, and smoothing explicit.
  • Identify missing observations, interpolated regions, and modeled values.
  • Check that colors, symbols, patterns, and labels remain distinguishable.
  • Avoid clipped annotations, truncated legends, or illegible text at final page size.
  • Use a suitable raster resolution or tested vector output without changing the scientific data.
  • Ensure sensitive geospatial locations or protected observations are not exposed inadvertently.

If the image requires changes to the plotted values or analytical method, create a new figure revision from the authoritative analysis rather than editing pixels to alter the findings.

6. Insert the figure in the correct report section

Because the deployed Reporting Studio interface has not been independently audited for this article, use the actual supported insert/attachment workflow rather than assuming a specific toolbar label or endpoint.

  1. Place the insertion point adjacent to the first substantive discussion of the figure.
  2. Choose the authorized figure artifact or publication-safe media representation.
  3. Confirm the selected ID and revision before attaching it to the report.
  4. Insert the figure without embedding credentials, private source URLs, or unrestricted access tokens.
  5. Set a readable display width; preserve aspect ratio and intended scales.
  6. Add a numbered caption and source attribution.
  7. Add suitable alternative text and a numerical or extended equivalent for complex graphics.
  8. Save a new controlled report revision and reopen it to verify persistence.

Where Reporting Studio only supports file insertion rather than version-bound scientific artifacts, document the file name, digest, source analysis, and approval evidence separately. Do not claim an automated provenance connection exists unless it is verified.

7. Write captions that explain the scientific result

A scientific caption should let readers understand the figure without searching the report for basic definitions. It should not merely repeat the report’s findings or introduce unsupported inference.

A useful caption normally provides the figure number; the plotted phenomenon or comparison; units and population, site, or period; necessary grouping and visual encoding; uncertainty or statistical conventions where relevant; and source or adaptation attribution.

Table 3. Caption quality examples
Type Caption Assessment
Insufficient Figure 2. Results. Does not identify variables, units, scope, or source
Better Figure 2. Synthetic measurements for control and treatment groups over 14 days; lines connect three observation times. Values are illustrative and do not establish a treatment effect. Identifies the comparison, temporal scope, and evidentiary limitation
Method-specific Figure 3. Modeled scenario outcomes under the assumptions described in Section 2.4. Shaded bands represent the stated model-uncertainty interval, not observed sampling variation. Distinguishes simulations from measurements and defines the uncertainty representation

The examples are synthetic teaching captions, not actual Sustainable Catalyst research findings.

8. Identify measurement units and axis transformations

Check units in the figure itself, the caption, the results narrative, and any numerical table. Inconsistent units can change the apparent magnitude of a finding.

Examples of issues to resolve include mass versus mass per area; annual versus cumulative quantities; Celsius versus Kelvin; proportions versus percentages; and CO2 versus CO2-equivalent.

For a ratio-based scale, record the denominator. For a normalized series, disclose the baseline and formula. For logarithmic axes, disclose the transformation and limitations, including treatment of zero and negative observations.

A caption cannot repair an incorrectly labeled axis; correct the source figure and produce a new controlled artifact.

9. Report uncertainty and statistical annotations

If a figure includes error bars, confidence bands, significance symbols, fitted curves, or estimated distributions, explain their meaning.

  • State whether error bars represent standard deviation, standard error, confidence intervals, quantiles, or another statistic.
  • Give the relevant sample size or denominator when material.
  • Describe model assumptions and interval coverage where they affect interpretation.
  • Explain symbols such as asterisks, superscripts, or threshold lines.
  • Do not infer statistical significance merely because plotted lines separate or error bars do not overlap.

Keep formal hypothesis-test results tied to the actual test, design, and multiplicity decisions. Avoid using visual styling to imply causal confidence that the study does not support.

10. Attribute third-party and adapted figures

Source attribution and permission are separate checks. An accurate citation does not automatically grant reproduction rights.

Determine whether the figure is:

  • Original: Created from project data or analysis; attribute the owning project or authors as appropriate.
  • Adapted: Derived from another author’s figure or data, with changes clearly noted and reuse rights established.
  • Reproduced: Copied from another work; verify the applicable license, permission, and required wording.
  • Derived from open data: Cite the dataset and analytical method, with any required attribution.

For a third-party image, record the original creator, publication, date, identifier, license, and changes. Use the applicable institutional or publisher citation style.

Do not remove source attribution simply because the chart was redrawn using different software.

11. Make the figure accessible

Scientific accessibility requires more than an image tag with a generic description. Provide the essential quantitative and interpretive content in a form that can be accessed without relying solely on vision or color.

  • Write concise alternative text that identifies the figure’s purpose.
  • Provide an extended description for complex patterns, maps, uncertainty, or multiseries figures.
  • Include an accessible data table or equivalent values when necessary.
  • Use line styles, markers, labels, and patterns rather than color alone.
  • Check applicable text and non-text contrast requirements.
  • For interactive figures, verify keyboard operation, focus indication, zoom, and alternatives to hover-only values.
  • Test relevant HTML, PDF, and other exports separately; successful editor rendering is insufficient.

WCAG 2.2 provides testable web-content requirements. Applicability and conformance must be evaluated for the actual rendered interface rather than inferred from a source graphing library.

12. Example: semantic HTML figure and caption

This example uses a synthetic image and companion numerical table. Replace placeholders with authorized URLs or relative media paths that actually exist. The example does not create a live Reporting Studio artifact.

<figure id="fig-2">
  <img src="synthetic-comparison.png"
       alt="Line chart comparing control and treatment
       values over 14 days; a numerical table follows."
       aria-describedby="fig-2-description">
  <figcaption>
    Figure 2. Synthetic control and treatment values
    at days 0, 7 and 14 (arbitrary units).
    Solid circles identify control; dashed squares
    identify treatment. This fixture supports no
    inferential or causal conclusion. Source:
    synthetic instructional dataset, revision 1.
  </figcaption>
</figure>
<div id="fig-2-description">
  <p>At day 0 both values are 10 units.
  At day 7, control is 11 and treatment is 14.
  At day 14, control is 12 and treatment is 17.
  Both series increase; no uncertainty estimates
  are available.</p>
</div>
<table>
  <caption>Values represented in Figure 2</caption>
  <thead><tr>
    <th scope="col">Day</th>
    <th scope="col">Control</th>
    <th scope="col">Treatment</th>
  </tr></thead>
  <tbody>
    <tr><th scope="row">0</th><td>10</td><td>10</td></tr>
    <tr><th scope="row">7</th><td>11</td><td>14</td></tr>
    <tr><th scope="row">14</th><td>12</td><td>17</td></tr>
  </tbody>
</table>

When copying this illustration into an actual report, change the source identity, description, values, and caption to match the validated project artifact. The table must not be treated as real observations.

13. Number figures and cross-reference them consistently

Use one numbering convention per report, such as Figure 1, Figure 2, and Figure 3, unless a journal or institutional template requires chapter-based numbering.

  1. Insert a clear reference to the figure near the relevant scientific claim.
  2. Ensure that the in-text figure reference resolves to the displayed figure.
  3. Reconcile numbering after inserting, deleting, or moving figures.
  4. Check that captions and references remain correct in all supported exports.
  5. Distinguish supplementary figures from main-text figures.

Do not assume automatically renumbered captions or dynamic cross-references are available without verifying the current editor and export behavior.

14. Keep captions synchronized with analysis revisions

If a source dataset, model, unit, sample count, or plotting procedure changes, reassess the figure and caption together.

For example, changing a figure from observed measurements to modeled projections requires more than replacing the image. The caption, methods, results, uncertainty explanation, and related claims may also need revision.

Record which report revision contains which figure revision. Do not silently replace a previously accepted figure with a new render that changes scientific meaning.

15. Replace a figure safely

  1. Locate the exact existing figure reference and report revision.
  2. Identify why replacement is necessary: layout, corrected data, improved accessibility, new analysis, or rights restriction.
  3. Preserve the previous authorized artifact according to applicable retention rules.
  4. Create or select the replacement artifact with a distinct revision identity.
  5. Reconcile numerical values, caption, units, provenance, and manuscript discussion.
  6. Assess whether the change is scientifically material and requires renewed review.
  7. Update the report through its supported save operation.
  8. Reload the document and inspect the inserted content.
  9. Revalidate HTML, DOCX, PDF, and publication outputs as applicable.

A new image file name by itself is not sufficient evidence of version control. Where publication has already occurred, follow the authorized correction or withdrawal policy rather than silently overwriting the public artifact.

16. Validate consistency between figure and narrative

The surrounding manuscript must not overstate the evidence displayed in the figure.

Table 4. Claim-to-figure checks
Question Acceptance expectation
Are reported values identical? Text, table, plotted marks, and source calculation reconcile
Are units consistent? Figure, caption, methods, and prose use compatible definitions
Is scope described correctly? Site, period, sample, and scenario correspond to the source evidence
Is interpretation justified? Correlation, causality, significance, and generalizability are not overclaimed
Is uncertainty explained? Intervals and assumptions match the analytical method
Is attribution complete? Source and reuse status are accurately represented

Visual appearance is not an independent scientific validation method. Review the data and analytical specification when verifying a quantitative figure.

17. Check exported figure fidelity

Once the report is saved, inspect the actual exported artifact—not just the editor preview.

Table 5. Export-specific figure checks
Format Required checks
HTML Image load, caption relationship, responsive sizing, text alternatives, table accessibility, public source permissions
DOCX Figure placement, numbering, caption styles, references, resolution, document accessibility
PDF Image clarity, font embedding where relevant, clipped content, captions, reading order, tags and appropriate text alternatives
Static image Correct revision, dimensions, labels, legibility, image integrity
Interactive figure Fallback behavior, authorized data access, keyboard interactions, preservation of scientific state

An export that completes successfully can still contain stale imagery, missing captions, substituted fonts, broken citations, or inaccessible content. Confirm that the export corresponds to the accepted manuscript and figure revisions.

18. Diagnose common insertion failures

Table 6. Frequent defects and first checks
Symptom Likely cause Safe next action
Blank figure box Broken media reference, permissions, or renderer dependency Inspect authorized artifact identity and sanitized error information
Old figure appears Stale report snapshot, cache, or mismatched revision Compare authoritative source and displayed revision
Caption does not match Manual text not updated after source change Reconcile figure, caption, and analysis evidence
Missing attribution Source metadata omitted or not carried to export Check reuse rights and required citation
Image too small or clipped Layout constraints, fixed dimensions, or raster scaling Adjust layout without altering scientific data
Axis labels unreadable Rendering size or font substitution Regenerate figure at intended publication dimensions
PDF differs from editor Export transformation, stale snapshot, or unsupported embedded content Inspect exact export source revision and rendering log
Insertion rejected Authorization, rights, object-type, or schema validation Verify actor, tenant, source permission, and supported format

Do not work around an access denial by copying private media into public storage.

19. Preserve figure provenance and audit evidence

A defensible publication record should allow an authorized reviewer to reconstruct the chain:

Source dataset and revision
          |
          v
Method, notebook, or model version
          |
          v
Scientific figure artifact and revision
          |
          v
Caption and source-attribution record
          |
          v
Reporting Studio manuscript revision
          |
          v
Scientific and editorial review
          |
          v
Authorized published export

Preserve links to the relevant source objects and reviewer evidence. Use content hashes where supported to detect unintended artifact changes, while recognizing that a matching hash proves identity of the bytes—not scientific validity.

20. Handle access restrictions and privacy

Figures can expose confidential geographic coordinates, unpublished analyses, personal data, or source material whose reuse is restricted.

  • Confirm the publication rights of each source dataset and image.
  • Inspect embedded metadata and filenames before public export.
  • Do not expose internal URLs containing tokens or signed credentials in public HTML.
  • Apply object-level permissions to both document and associated figure.
  • Check that a public figure cannot reveal a private source through previews, downloads, or related-object links.
  • Respect legal erasure, restrictions, and applicable retention requirements.

When legal or privacy considerations require restricting an already published figure, follow the controlled correction and removal workflow rather than manually concealing the image while leaving other copies public.

21. Separate draft, reviewed, approved, and published states

A proposed figure lifecycle may be:

Draft figure
    |
    v
Numerical and provenance review
    |
    v
Caption and accessibility review
    |
    v
Report revision accepted
    |
    v
Separate publication authorization
    |
    v
Public document and permitted figure

This illustrates recommended governance; it is not a verified Reporting Studio state machine. A later material change to the source data or caption may require a new report revision and renewed scientific assessment.

22. Perform final acceptance checks

Table 7. Figure insertion acceptance matrix
Criterion Pass condition
Correct report context Authorized project, report, and revision identified
Artifact identity Selected figure matches the intended source and exact revision
Numerical fidelity Plotted values reconcile with verified analysis outputs
Units and scales Dimensions, transformations, and axes correctly defined
Uncertainty Statistical and modeled intervals accurately described
Caption Number, scientific subject, scope, and necessary explanation present
Attribution and rights Source and permitted reuse established
Accessibility Applicable alternatives and interaction tests completed
Claim consistency Textual findings and figure evidence agree
Persistence Figure and caption survive save and reload
Exports Each supported released format reflects the approved figure
Publication governance Required scientific, editorial, rights, and publication decisions complete

Decision rule: Use Pass, Fail, Not Tested, or Not Applicable for each criterion. Do not approve publication if a mandatory scientific, rights, authorization, or privacy control is failed or untested.

23. Record an example acceptance receipt

The following is a proposed diagnostic and acceptance object, not a verified application API contract.

{
  "schema_version": "figure-insertion-acceptance-example-v1",
  "classification": "proposed",
  "application": "reporting_studio",
  "report_id": "synthetic-report-017",
  "report_revision": "draft-2",
  "figure_id": "synthetic-figure-003",
  "figure_revision": "render-1",
  "checks": {
    "identity_and_permissions": "not_tested",
    "figure_source_revision": "not_tested",
    "numerical_fidelity": "not_tested",
    "units_and_scales": "not_tested",
    "uncertainty": "not_tested",
    "caption_accuracy": "not_tested",
    "source_attribution": "not_tested",
    "rights_and_privacy": "not_tested",
    "accessible_equivalents": "not_tested",
    "narrative_consistency": "not_tested",
    "save_and_reload": "not_tested",
    "html_export": "not_tested",
    "docx_export": "not_tested",
    "pdf_export": "not_tested",
    "scientific_review": "not_tested",
    "publication_authorization": "not_tested"
  },
  "publication_approved": false,
  "release_decision": "NO_GO"
}

Do not substitute a fabricated approval token or checklist field for actual trusted review decisions.

24. Recover safely from insertion or export errors

  1. Identify the affected report and original figure revision.
  2. Preserve the last accepted report and authorized figure artifact.
  3. Determine whether the attempted insert, replace, or export command actually committed.
  4. Inspect a sanitized error or trace ID and classify the failure.
  5. Confirm current permissions, source rights, and relevant schema versions.
  6. Repair only the responsible binding, caption, render, or export configuration.
  7. Use a controlled revision if the scientific content changes.
  8. Reload the document and verify figure identity and caption persistence.
  9. Rerun applicable scientific, accessibility, rights, and output checks.
  10. Escalate unresolved defects with a sanitized minimal reproduction and observed-versus-expected behavior.

Do not blindly replay uncertain writes, overwrite approved artifacts, or restore private content to a public endpoint to fix a missing figure.

25. Platform implementation and verification boundaries

Before classifying this procedure as production verified, attach the actual Reporting Studio repository and deployed revision; supported figure storage and binding contracts; rendered HTML/DOCX/PDF behavior; identity and source-access enforcement; provenance and citation relationships; migration and rollback evidence; and executed staging and public-output tests.

Intended responsibilities include Workbench and Research Lab for scientific outputs, Library for source references, Research for evidence relationships, Workspace for review and publication governance, Site Intelligence for geospatial figures, Reporting Studio for document composition, and Research Hub for approved public display. Verify each integration rather than assuming a shared interface is live.

26. Technical and scientific references

  1. World Wide Web Consortium (W3C). Web Content Accessibility Guidelines (WCAG) 2.2. https://www.w3.org/TR/WCAG22/.
  2. W3C Web Accessibility Initiative. Complex Images. https://www.w3.org/WAI/tutorials/images/complex/.
  3. W3C. PROV-O: The PROV Ontology. https://www.w3.org/TR/prov-o/.
  4. Wilkinson, M.D. et al. (2016). ‘The FAIR Guiding Principles for Scientific Data Management and Stewardship’, Scientific Data, 3, 160018. https://doi.org/10.1038/sdata.2016.18.
  5. Matplotlib Development Team. Matplotlib documentation. https://matplotlib.org/stable/.
  6. International Committee of Medical Journal Editors (ICMJE). Recommendations for the Conduct, Reporting, Editing, and Publication of Scholarly Work in Medical Journals. https://www.icmje.org/recommendations/. Apply field-specific reporting guidance where appropriate.

27. Completion and verification record

Completion criterion: A scientific figure insertion is accepted when its rendered content corresponds to the exact authorized source artifact and revision; numerical values, units, transformations, uncertainty, caption, attribution, and accessibility alternatives are correct; the manuscript’s interpretation is consistent with the evidence; and saved and exported versions preserve the required relationships.

Scientific limitation: Reproducible rendering, accurate captions, and matching source checksums do not establish the validity of an experiment, statistical method, model, or causal inference. Scientific assessment remains a distinct responsibility.

Current implementation status: Proposed figure insertion, caption composition, source attribution, accessibility, version control, export verification, safe replacement, recovery, and acceptance procedures documented. No actual Sustainable Catalyst Reporting Studio figure insertion tool, Workbench bridge, citation integration, or deployed publication behavior has been independently validated through this article.

Scroll to Top