Worked Examples

Understand figure source reconciliation — Visualization & Graphing

Understand figure source reconciliation — Visualization & Graphing Cross-application area: Visualization & Graphing Status: Initial scientific graphics guidance; platform-specific features not verified. Why this visualization matt

ProductSustainable Catalyst Research LabUpdatedNovember 14, 2026Reading time1 minutes

Cross-application area: Visualization & Graphing
Classification: Scientific Methods / Data Provenance / Figure Verification
Audience: Researchers, scientific programmers, data analysts, visualization developers, and research reviewers
Technical level: Intermediate to advanced
Reference environment: Python 3 standard library
Primary outputs: Source-to-figure reconciliation report, numerical validation, provenance record, and scientific review evidence
Estimated reading time: 13–16 minutes; 25–35 minutes including practical exercises

1. What is figure source reconciliation?

Figure source reconciliation is the process of verifying that the numerical values represented in a scientific figure agree with the authoritative source data, documented calculations, and graphical transformation rules used to produce it.

It establishes an auditable relationship between a figure and the evidence underlying its scientific claims.

For example, a graph may show the mean response of an experimental group. Source reconciliation determines whether that mean can be reproduced from the correct observations, using the stated calculation and data selection.

It also asks whether the graphical renderer correctly represents the calculated value.

Primary quality condition: Displayed values must agree with the authoritative analytical results and their documented transformation rules. Differences must be explained, justified, and reproducible.

A figure can appear visually correct while containing incorrectly grouped observations, inconsistent units, stale calculations, or misleading graphical transformations.

2. Why figure source reconciliation matters

Scientific figures are frequently used to support research findings, policy recommendations, model comparisons, and technical decisions.

Readers may reasonably interpret a plotted point as representing a measured observation, a statistical estimate, or a verified model output.

Without reconciliation, the origin of that point may be unclear.

Common risks include:

  • Displaying results from the wrong source dataset or revision.
  • Using an outdated analytical result after the source data have changed.
  • Incorrect filtering, grouping, or aggregation.
  • Mixing measurement units.
  • Presenting interpolated or modeled results as observations.
  • Omitting records without documenting the exclusions.
  • Plotting values that differ from the accepted analytical output.
  • Misrepresenting uncertainty bounds.
  • Publishing a figure that cannot be independently reproduced.

Source reconciliation is therefore both a numerical verification practice and a provenance requirement.

3. Understand the evidence chain

A scientific figure typically depends on multiple related artifacts.

Authoritative source dataset
             |
             v
Data selection and quality controls
             |
             v
Documented analytical transformation
             |
             v
Immutable analytical output
             |
             v
Figure numerical data
             |
             v
Graphical encoding and scale
             |
             v
Rendered figure
             |
             v
Reviewed research publication

Each layer answers a different verification question.

Table 1. Levels of figure source reconciliation
Layer Verification question
Source dataset Are these the authoritative observations and correct revision?
Selection Were the intended records included and excluded?
Transformation Were calculations performed using the stated method?
Analytical output Does the persisted numerical result match independent recomputation?
Figure data Does the renderer receive the accepted numerical values?
Rendered marks Are graphical positions, intervals, labels, and scales correct?
Publication Does the published figure correspond to the approved version?

A checksum verifies the integrity of a particular representation of data. It does not independently establish scientific accuracy or correct analysis.

Likewise, numerical agreement between an analytical output and a figure does not establish that the analytical method was scientifically appropriate.

4. Define the scientific question and figure semantics

Before reconciling numerical values, identify the purpose of the figure.

Record:

  • The scientific research question.
  • The intended comparison or relationship.
  • The observation or experimental unit.
  • The variables and their physical or statistical meaning.
  • The source dataset and revision.
  • The measurement units.
  • The temporal or geographic coverage.
  • The transformations or statistical methods used.
  • The relevant uncertainty definition.
  • The intended audience and scientific inference.

For example, a figure showing an arithmetic mean is not equivalent to one showing a median, total, model prediction, or directly measured observation.

Reconciliation must verify the type of value being presented rather than comparing numbers without context.

5. Define the mathematical reconciliation process

Let D represent an authoritative dataset, S the selection state, and T the analytical transformation.

The analytical output is:

A = T(D, S)

Let P represent the operation that prepares numerical values for plotting:

F = P(A)

Let R represent the renderer and C its graphical configuration:

G = R(F, C)

Reconciliation examines three related relationships:

  1. Does independent recomputation of T(D, S) agree with A?
  2. Does the numerical figure input F agree with the accepted analytical artifact?
  3. Does the rendered figure G faithfully encode F under configuration C?

These checks should be performed separately because they detect different defects.

A correct mean calculation cannot prevent the renderer from placing a point at the wrong value. A correct renderer cannot repair a mean calculated from the wrong observations.

6. Preserve authoritative source and analytical revisions

Reconciliation should use identifiable, versioned artifacts rather than an unrecorded live query whose results may change.

Relevant metadata include:

Table 2. Recommended source and analysis metadata
Field Purpose
source_artifact_id Identifies the authoritative dataset
source_revision Identifies the data version used
source_checksum Supports verification that source content has not changed
contributing_records Identifies the observations used
selection_state Records filters and exclusions
transformation_id Identifies the analytical method
analysis_revision Identifies the calculation implementation
analytical_artifact_id Identifies the persisted numerical result
figure_revision Identifies the graphical output version
renderer_version Identifies the graphics software
review_status Separates generated results from reviewed evidence

Calling a file immutable does not make it immutable. Actual storage controls, revision management, and access policies must support that claim.

For a scientific publication, the figure should resolve to the specific analytical result used at the time of approval, not automatically to the latest available calculation.

7. Reconcile individual records and aggregated values

Reconciliation may be straightforward when a figure displays individual measurements.

For each plotted observation, confirm that its identifier, value, and units match the authoritative source.

For aggregated figures, identify all records contributing to each summary.

For the arithmetic mean of a group:

mean = sum(x_i) / n

where n is the number of contributing observations.

The contributing record set is important. Two calculations can have the same count but use different observations.

For example:

Group A:
10, 12

Correct mean:
11

A plotted value of 12 would fail reconciliation if the documented transformation were the arithmetic mean of those two observations.

Changing the figure caption to justify the value would not constitute a valid correction without an actual analytical explanation.

8. Reconcile transformations and measurement units

Figures often display values that differ numerically from source observations because an authorized transformation has been performed.

Common examples include:

  • Filtering and exclusion.
  • Grouping and aggregation.
  • Unit conversion.
  • Normalization.
  • Resampling.
  • Smoothing.
  • Interpolation.
  • Statistical estimation.
  • Model prediction.

Each operation requires a recorded method and appropriate parameters.

8.1 Unit conversion

For example:

mass_kg = mass_g / 1000

If the authoritative source reports grams and the figure reports kilograms, the values should be compared after applying the validated conversion.

8.2 Normalization

A rate requires a defined denominator:

rate = numerator / denominator

A graph showing tonnes of CO₂ per hectare cannot be reconciled to an original mass total unless the corresponding area is known and properly used.

8.3 Smoothing and interpolation

These methods may create derived values between source observations.

Record the algorithm, parameters, input records, and the distinction between observed and estimated values.

Interpolated points must not be presented as newly measured observations.

9. Use a synthetic worked example

Consider four synthetic observations divided between two groups.

Table 3. Synthetic source observations
Record ID Day Group Response (synthetic units)
A00 0 A 10
A07 7 A 12
B00 0 B 14
B07 7 B 18

The intended figure compares group means.

Expected calculations:

Group A:
(10 + 12) / 2 = 11

Group B:
(14 + 18) / 2 = 16
Table 4. Expected figure values
Figure mark Contributing records Expected value
mean_A A00, A07 11
mean_B B00, B07 16

These observations are synthetic. They do not support a real experimental inference.

The purpose of the exercise is to demonstrate source-to-summary and summary-to-figure reconciliation.

10. Create a reproducible reconciliation module

10.1 Prepare the environment

mkdir figure-source-reconciliation
cd figure-source-reconciliation

python3 -m venv .venv
source .venv/bin/activate

python --version

The following example uses Python’s standard library and does not require access to any Sustainable Catalyst service.

10.2 Create the source and reconciliation functions

Save as reconcile_figure.py.

from dataclasses import dataclass
from hashlib import sha256
import json
import math


@dataclass(frozen=True)
class Observation:
    record_id: str
    group: str
    value: float


@dataclass(frozen=True)
class FigureMark:
    group: str
    value: float
    units: str
    contributors: tuple[str, ...]


SOURCE = (
    Observation("A00", "A", 10.0),
    Observation("A07", "A", 12.0),
    Observation("B00", "B", 14.0),
    Observation("B07", "B", 18.0)
)


SOURCE_VERSION = "synthetic-v1"
TRANSFORMATION = "group-mean-v1"


def validate_source(rows):
    if not rows:
        raise ValueError("Empty source")

    ids = [row.record_id for row in rows]

    if len(ids) != len(set(ids)):
        raise ValueError(
            "Duplicate source record"
        )

    for row in rows:
        if not row.record_id or not row.group:
            raise ValueError(
                "Missing source metadata"
            )

        if not math.isfinite(row.value):
            raise ValueError(
                "Nonfinite source value"
            )

    return True


def source_checksum(rows):
    validate_source(rows)

    payload = [
        {
            "id": row.record_id,
            "group": row.group,
            "value": row.value
        }
        for row in rows
    ]

    serialized = json.dumps(
        payload,
        sort_keys=True,
        separators=(",", ":"),
        allow_nan=False
    ).encode("utf-8")

    return sha256(serialized).hexdigest()


def compute_means(rows):
    validate_source(rows)

    grouped = {}

    for row in rows:
        grouped.setdefault(
            row.group, []
        ).append(row)

    result = {}

    for group, members in sorted(
        grouped.items()
    ):
        result[group] = {
            "value": (
                math.fsum(
                    row.value for row in members
                ) / len(members)
            ),
            "contributors": tuple(
                sorted(
                    row.record_id
                    for row in members
                )
            ),
            "count": len(members)
        }

    return result


def expected_marks(rows):
    summaries = compute_means(rows)

    return tuple(
        FigureMark(
            group=group,
            value=summary["value"],
            units="synthetic units",
            contributors=summary["contributors"]
        )
        for group, summary in summaries.items()
    )


def reconcile(rows, marks, tolerance=1e-12):
    reference = compute_means(rows)

    if not (
        math.isfinite(tolerance)
        and tolerance >= 0
    ):
        raise ValueError(
            "Invalid tolerance"
        )

    groups = [mark.group for mark in marks]

    if len(groups) != len(set(groups)):
        raise ValueError(
            "Duplicate figure group"
        )

    if set(groups) != set(reference):
        raise ValueError(
            "Figure group mismatch"
        )

    results = []

    for mark in marks:
        expected = reference[mark.group]

        if mark.units != "synthetic units":
            raise ValueError(
                "Incorrect figure units"
            )

        if not math.isfinite(mark.value):
            raise ValueError(
                "Nonfinite figure value"
            )

        if tuple(sorted(mark.contributors)) != (
            expected["contributors"]
        ):
            raise ValueError(
                "Contributor mismatch"
            )

        if not math.isclose(
            mark.value,
            expected["value"],
            rel_tol=0,
            abs_tol=tolerance
        ):
            raise ValueError(
                "Numerical mismatch"
            )

        results.append({
            "group": mark.group,
            "expected": expected["value"],
            "displayed": mark.value,
            "status": "PASS"
        })

    return results


if __name__ == "__main__":
    marks = expected_marks(SOURCE)

    report = {
        "source_version": SOURCE_VERSION,
        "source_sha256": source_checksum(
            SOURCE
        ),
        "transformation": TRANSFORMATION,
        "reconciliation": reconcile(
            SOURCE, marks
        ),
        "renderer_review": "not_tested",
        "scientific_review": "not_tested"
    }

    print(
        json.dumps(report, indent=2)
    )

10.3 Execute the example

python reconcile_figure.py

Expected reconciliation values:

Group A:
Expected = 11
Displayed = 11
Status = PASS

Group B:
Expected = 16
Displayed = 16
Status = PASS

The reported SHA-256 digest identifies the canonical serialized source content used in the example.

The example does not create an immutable analytical artifact or rendered image. Those require separate persistence and renderer acceptance procedures.

11. Test incorrect figure values and source revisions

Reconciliation should reject a figure whose values, contributors, or measurement units do not match the declared source and transformation.

Save as test_reconcile_figure.py.

from dataclasses import replace
import math
import unittest

from reconcile_figure import (
    SOURCE,
    compute_means,
    expected_marks,
    reconcile,
    source_checksum,
    validate_source
)


class ReconciliationTests(unittest.TestCase):

    def test_reference_values(self):
        result = compute_means(SOURCE)

        self.assertEqual(
            result["A"]["value"], 11.0
        )

        self.assertEqual(
            result["B"]["value"], 16.0
        )

    def test_valid_reconciliation(self):
        result = reconcile(
            SOURCE,
            expected_marks(SOURCE)
        )

        self.assertEqual(len(result), 2)

    def test_wrong_value_rejected(self):
        marks = list(expected_marks(SOURCE))

        marks[0] = replace(
            marks[0],
            value=12.0
        )

        with self.assertRaises(ValueError):
            reconcile(SOURCE, marks)

    def test_wrong_contributors_rejected(self):
        marks = list(expected_marks(SOURCE))

        marks[0] = replace(
            marks[0],
            contributors=("A00", "B00")
        )

        with self.assertRaises(ValueError):
            reconcile(SOURCE, marks)

    def test_wrong_units_rejected(self):
        marks = list(expected_marks(SOURCE))

        marks[0] = replace(
            marks[0],
            units="kg"
        )

        with self.assertRaises(ValueError):
            reconcile(SOURCE, marks)

    def test_missing_group_rejected(self):
        marks = expected_marks(SOURCE)

        with self.assertRaises(ValueError):
            reconcile(SOURCE, marks[:1])

    def test_duplicate_source_rejected(self):
        with self.assertRaises(ValueError):
            validate_source(
                SOURCE + (SOURCE[0],)
            )

    def test_nonfinite_source_rejected(self):
        changed = list(SOURCE)

        changed[0] = replace(
            changed[0],
            value=math.inf
        )

        with self.assertRaises(ValueError):
            validate_source(tuple(changed))

    def test_checksum_change_detected(self):
        changed = list(SOURCE)

        changed[0] = replace(
            changed[0],
            value=99.0
        )

        self.assertNotEqual(
            source_checksum(SOURCE),
            source_checksum(tuple(changed))
        )

    def test_checksum_stability(self):
        self.assertEqual(
            source_checksum(SOURCE),
            source_checksum(tuple(SOURCE))
        )

    def test_invalid_tolerance_rejected(self):
        with self.assertRaises(ValueError):
            reconcile(
                SOURCE,
                expected_marks(SOURCE),
                tolerance=-1
            )


if __name__ == "__main__":
    unittest.main()

Execute:

python -m unittest -v test_reconcile_figure.py

The reference suite defines eleven tests for numerical values, contributor membership, units, group coverage, invalid data, checksums, and tolerance handling.

They are provided as reproducible examples and are not represented as tests executed against Sustainable Catalyst.

12. Validate the rendered figure independently

Passing numerical reconciliation does not establish that the graphic correctly displays the validated values.

For example, the expected group means may be 11 and 16, but a renderer configuration could place the corresponding marks at incorrect positions.

Renderer-specific acceptance should verify:

  • The number and identity of plotted marks.
  • The numerical values associated with each mark.
  • Category order and coordinate mappings.
  • Axis units and scale types.
  • Correct uncertainty bounds.
  • Clipping and missing-data behavior.
  • Data-to-mark mapping after interactive filtering.
  • Consistency between preview and exported figures.

Where supported, inspect the renderer’s numerical mark data or scene specification. An image checksum alone does not establish graphical correctness.

Maintain the numerical figure-data table alongside the rendered artifact so that reviewers can inspect actual values independently.

13. Reconcile interactive and filtered figures

Interactive visualizations may produce different figures as researchers select alternative groups, date ranges, or geographic regions.

Each rendered state should have a reconstructable selection specification.

For example:

Selection 1:
Group = A
Days = 0 and 7

Expected mean = 11

Selection 2:
Group = A
Day = 7 only

Expected value = 12

Both results may be correct, but they represent different analytical states.

Record relevant filters, source revisions, and transformation settings before creating a persistent figure snapshot.

Do not confuse a temporary browser interaction with an approved and immutable analytical result.

14. Reconcile uncertainty and statistical summaries

Figures may include confidence intervals, prediction intervals, measurement uncertainty, or other summary statistics.

These require more than a comparison of point estimates.

For each uncertainty display, verify:

  • Contributing observations.
  • Sample size and grouping.
  • Statistical estimator.
  • Uncertainty type and coverage level.
  • Statistical or metrological assumptions.
  • Lower and upper bounds.
  • Measurement units.
  • Graphical interval geometry.

A figure may correctly display its point estimate while showing an incorrect or mislabeled interval.

Reconcile uncertainty bounds with their own documented calculations rather than treating error bars as decorative elements.

15. Reconcile temporal, spatial, and modeled figures

15.1 Temporal evidence

Time-series figures must preserve the intended observation timestamps, time standard, aggregation period, and missing-data treatment.

When values are resampled or interpolated, identify those transformations and avoid presenting estimated intermediate values as direct observations.

15.2 Geospatial evidence

Geographic figures require source reconciliation across coordinate reference systems, projections, spatial extents, and raster or vector transformations.

Check that mapped values correspond to the correct source locations and observation dates.

Satellite imagery, spatial interpolation, and rendered three-dimensional surfaces require explicit differentiation between observed data and processed or modeled values.

15.3 Simulated evidence

For simulation outputs, preserve the model version, initial conditions, relevant parameters, numerical method, and random seed where applicable.

A deterministic rendering of a simulated trajectory does not make the simulated values empirical measurements.

16. Preserve source and transformation provenance

Source reconciliation requires more than a figure caption containing a publication citation.

An effective provenance record should identify relationships among:

  • Source datasets.
  • Contributing records.
  • Analytical activities.
  • Generated numerical artifacts.
  • Figure configurations.
  • Rendered outputs.
  • Review and publication decisions.

W3C PROV-O provides a standardized ontology for describing entities, activities, and agents involved in provenance relationships (W3C, 2013).

Such relationships can help distinguish the source of a value from the process that transformed it and the person or system responsible for an activity.

Using a provenance model does not automatically establish that the recorded relationships are true. The corresponding source and execution evidence must still be verified.

17. Scientific acceptance criteria

Table 5. Figure source-reconciliation acceptance matrix
Criterion Pass condition
Source identity Correct authoritative dataset and revision established
Source integrity Expected source content verified against its integrity record
Contributor membership Each result uses its intended observations
Selection state Filters and exclusions can be reconstructed
Analytical transformation Methods and parameters are documented and reproducible
Numerical reconciliation Recomputed values agree with accepted analytical output
Unit consistency Source and display units are compatible and correctly converted
Uncertainty Statistical bounds agree with the specified methods
Graphical marks Displayed values correspond to the validated figure-data table
Axis and scale Scale transformations preserve intended numerical meaning
Accessibility Essential information has an accessible numerical equivalent
Reproducibility Approved output can be reconstructed from preserved evidence
Scientific review Interpretation is appropriate to the data and method
Publication approval Published figure references the accepted revision

Acceptance rule: Record each applicable criterion as Pass, Fail, Not Tested, or Not Applicable. A figure cannot be considered fully reconciled when a required source, analytical transformation, or graphical value remains unexplained.

18. Prepare a provenance and reconciliation manifest

A machine-readable record can connect figure values with their underlying evidence.

{
  "schema_version": "example-1.0",
  "figure_id": "synthetic-group-means",
  "source": {
    "artifact_id": "synthetic-source",
    "revision": "synthetic-v1",
    "classification": "synthetic",
    "sha256": null
  },
  "analysis": {
    "artifact_id": "synthetic-analysis",
    "transformation": "group-mean-v1",
    "method": "arithmetic_mean"
  },
  "figure_marks": [
    {
      "group": "A",
      "value": 11.0,
      "units": "synthetic_units",
      "contributors": ["A00", "A07"]
    },
    {
      "group": "B",
      "value": 16.0,
      "units": "synthetic_units",
      "contributors": ["B00", "B07"]
    }
  ],
  "validation": {
    "source_integrity": "not_tested",
    "analytical_reconciliation": "not_tested",
    "figure_data": "not_tested",
    "renderer": "not_tested",
    "accessibility": "not_tested",
    "scientific_review": "not_tested"
  },
  "publication_approval": "not_approved"
}

This is an illustrative evidence structure, not a verified Sustainable Catalyst API contract.

Actual source hashes, analytical artifact identifiers, renderer versions, test receipts, and reviewer decisions must come from executed workflows.

19. Sustainable Catalyst integration

Figure source reconciliation is relevant to the intended connection between Sustainable Catalyst’s research-data infrastructure, reproducible analysis tools, scientific visualization, and publication workflows.

Table 6. Proposed cross-application responsibilities
Application Intended responsibility
Library Preserve source datasets, identifiers, versions, metadata, rights, and provenance
Workbench Produce reproducible analytical outputs and figure-data tables where implemented
Research Lab Evaluate analytical correctness, statistics, uncertainty, and scientific assumptions
Visualization & Graphing Map numerical results to validated graphical marks and exports
Site Intelligence Support geographic source reconciliation and coordinate transformations where implemented
Decision Studio Preserve model and scenario evidence relationships where supported
Workspace Track analytical revisions, figure evidence, review decisions, and approvals
Research Publish approved figures with their methods, source citations, and provenance

These are intended architectural responsibilities, not claims that every integration has been deployed and accepted.

19.1 Platform verification requirement

Before certifying a Sustainable Catalyst source-reconciliation capability, verify:

  • Owning repository and implementation revision.
  • Actual source and analytical artifact schemas.
  • Source-to-analysis lineage mappings.
  • Transformation and calculation code paths.
  • Renderer engine and version.
  • Numerical mark contracts.
  • Persistence and revision behavior.
  • Source rights and authorization.
  • Executed numerical and negative tests.
  • Rendered figures and export evidence.
  • Independent review and release approval.

The availability of a rendering library or source citation does not establish complete figure provenance.

20. Scientific limitations and escalation

Escalate for scientific or engineering review when:

  • Figure values cannot be reproduced.
  • Source observations or analytical revisions cannot be identified.
  • Contributing records are inconsistent.
  • Transformations are undocumented.
  • Unit conversions are incorrect or ambiguous.
  • Rendered marks differ from the figure-data table.
  • Statistical uncertainty cannot be reconstructed.
  • Temporal or spatial alignment is inconsistent.
  • A published research claim depends on an unreconciled figure.

Preserve the original figure and relevant artifacts during investigation.

If a material discrepancy affects published research, review and document an appropriate correction instead of silently overwriting the original output.

21. Technical references

  1. World Wide Web Consortium (W3C) (2013). PROV-O: The PROV Ontology. W3C Recommendation. Available at: https://www.w3.org/TR/prov-o/.
  2. World Wide Web Consortium (W3C) (2013). PROV-DM: The PROV Data Model. W3C Recommendation. Available at: https://www.w3.org/TR/prov-dm/.
  3. National Institute of Standards and Technology (NIST) (2015). Secure Hash Standard (SHS). FIPS PUB 180-4. Available at: https://doi.org/10.6028/NIST.FIPS.180-4.
  4. Python Software Foundation (n.d.). math — Mathematical Functions. Available at: Python documentation.
  5. Python Software Foundation (n.d.). hashlib — Secure Hashes and Message Digests. Available at: Python documentation.
  6. Python Software Foundation (n.d.). unittest — Unit Testing Framework. Available at: Python documentation.
  7. Vega-Lite Developers (n.d.). Data Transformations. Available at: Vega-Lite documentation.
  8. Matplotlib Development Team (n.d.). Matplotlib Documentation. Available at: https://matplotlib.org/stable/.
  9. World Wide Web Consortium (W3C) (2024). Web Content Accessibility Guidelines (WCAG) 2.2. Available at: https://www.w3.org/TR/WCAG22/.
  10. W3C Web Accessibility Initiative (n.d.). Complex Images. Available at: W3C WAI guidance.

22. Completion and verification record

Table 7. Required figure source-reconciliation record
Field Required evidence
Figure identifier Figure and revision
Source identity Dataset identifier, revision, and checksum
Analytical output Versioned numerical artifact and method
Contributor integrity Pass, Fail, or Not Tested
Selection state Pass, Fail, or Not Tested
Transformation correctness Pass, Fail, or Not Tested
Numerical reconciliation Pass, Fail, or Not Tested
Unit consistency Pass, Fail, or Not Tested
Uncertainty reconciliation Pass, Fail, Not Tested, or Not Applicable
Figure-data integrity Pass, Fail, or Not Tested
Rendered mark fidelity Pass, Fail, or Not Tested
Accessibility Pass, Fail, or Not Tested
Reproducibility Pass, Fail, or Not Tested
Scientific review Pass, Fail, or Not Tested
Publication approval Approved, Not Approved, or Not Applicable
Reviewer Actual reviewer and review date
Evidence artifacts Source records, analytical outputs, tests, figure specifications, and rendering evidence
Outstanding limitations Unresolved scientific or implementation concerns

Completion criterion: A figure is reconciled when its source and analytical revisions are identifiable, contributing observations and transformations can be independently verified, numerical figure values agree with accepted analytical outputs, graphical marks faithfully encode those values, and applicable scientific and publication-review requirements are satisfied.

Scientific limitation: Reconciliation demonstrates traceability and consistency between source evidence and graphical output. It does not independently establish that source measurements are accurate, the analytical method is appropriate, or the resulting scientific inference is valid.

Current implementation status: Figure provenance methodology, synthetic reference dataset, numerical reconciliation module, regression test definitions, and proposed acceptance criteria documented. No particular Sustainable Catalyst source-lineage service, immutable analytical store, renderer, or publication integration is certified without implementation-specific source audit, executed tests, rendering inspection, and release acceptance evidence.

Scroll to Top