Worked Examples
Understand axis scales and units — Visualization & Graphing
Understand axis scales and units — Visualization & Graphing Cross-application area: Visualization & Graphing Status: Initial scientific graphics guidance; platform-specific features not verified. Why this visualization matters Use
Application area: Visualization & Graphing
Article classification: Scientific methods / Axis scales / Measurement units
Audience: Researchers, scientific programmers, visualization developers, data analysts, and publication reviewers
Technical level: Intermediate
Reference environment: Python 3, NumPy, Matplotlib, and pytest
Scientific conventions: SI units, dimensional analysis, explicitly documented transformations, and reproducible graphical encoding
Primary outputs: Validated axis specification, unit-conversion record, reproducible figure, numerical checks, and scientific review evidence
Estimated reading time: 13–16 minutes, excluding exercises
1. Why axis scales and units matter
An axis converts scientific measurements into graphical positions. Its labels, measurement units, limits, transformations, and direction determine how readers perceive numerical relationships.
Incorrect axis design may:
- Exaggerate differences between measurements.
- Conceal positive or negative values.
- Compress important scientific variation.
- Imply a nonexistent zero or natural baseline.
- Confuse measured values with transformed values.
- Present incompatible physical quantities as directly comparable.
- Misrepresent the magnitude or direction of change.
- Hide observations through inappropriate clipping or scaling.
For example, a chart displaying carbon dioxide removal in tonnes of CO₂ must not silently substitute tonnes of carbon. These quantities are related but not numerically equivalent.
Primary quality requirement: The plotting range, axis transformation, and stated measurement units must preserve the scientific meaning of the represented quantities without exaggerating differences, concealing sign, or introducing unsupported comparisons.
Axis choices must be justified in relation to the research question and the graphical marks used.
2. Identify the scientific quantity before selecting a scale
Each plotted variable should have a documented physical or statistical meaning.
| Property | Example | Validation question |
|---|---|---|
| Variable name | Soil temperature | What quantity is being measured? |
| Unit | °C | Is the unit correct and consistently applied? |
| Measurement type | Continuous | Is the selected scale appropriate? |
| Observed range | 5–25 °C | Are relevant values visible? |
| Reference value | 0 °C | Does zero have the implied meaning? |
| Uncertainty | ±0.5 °C | Are uncertainty units and definitions compatible? |
| Temporal coverage | Specified observation period | Are timestamps and aggregation intervals consistent? |
| Data provenance | Versioned sensor dataset | Can plotted values be traced to source data? |
Not every zero has the same scientific meaning. Zero degrees Celsius does not represent an absence of thermodynamic temperature, whereas zero kilograms denotes an absence of mass under the usual interpretation.
Similarly, an ordinal score should not be treated as an absolute physical measurement merely because it is represented numerically.
3. Understand common axis scales
| Scale | Typical use | Scientific caution |
|---|---|---|
| Linear | Measurements where equal differences should have equal visual spacing | Inspect limits and baselines |
| Logarithmic | Positive measurements spanning several orders of magnitude | Cannot directly represent zero or negative values on an ordinary logarithmic axis |
| Symmetric logarithmic | Signed quantities spanning substantially different magnitudes | Transformation and near-zero linear region must be disclosed |
| Categorical | Distinct groups or classifications | Do not imply quantitative distances between nominal categories |
| Temporal | Observation and event times | Preserve actual temporal spacing and time reference |
| Probability or specialized transformation | Specific statistical analyses | Requires an explicit mathematical definition and appropriate domain |
Matplotlib provides linear, logarithmic, symmetric-logarithmic, and other scaling options. Their availability does not establish scientific suitability in a particular application (Matplotlib Development Team, n.d.).
4. Linear scales and proportional interpretation
A linear graphical mapping may be expressed as:
p = a*x + b
where:
xis the numerical measurement.pis its graphical position.ais the scale factor.bis the position offset.
Equal increments in x produce equal graphical position changes.
4.1 Zero-baseline bars
For bar charts encoding nonnegative magnitudes through length, a zero baseline is generally important for proportional comparisons.
Consider:
Group A = 10
Group B = 12
Actual magnitude ratio:
12 / 10 = 1.2
If the visible bar baseline is 9:
Visible A length = 10 - 9 = 1
Visible B length = 12 - 9 = 3
Visible length ratio = 3
The truncated representation exaggerates the apparent magnitude difference.
A zero-baseline bar chart or a clearly labeled dot plot may be more appropriate depending on the intended comparison.
4.2 Line and point charts
A truncated axis is not automatically inappropriate for point or line charts, because these marks generally encode position rather than bar length.
However, the limits must be clear and the selected range must not conceal relevant context or alter the scientific interpretation without disclosure.
5. Preserve positive and negative values
Signed quantities are common in scientific research.
Examples include:
- Temperature anomalies.
- Net carbon fluxes under a defined sign convention.
- Residuals from statistical models.
- Changes relative to a baseline.
- Financial or economic balances.
- Measurement deviations.
Consider a synthetic dataset:
-4, -2, 0, 3, 5
An axis limited to positive values would conceal the negative observations.
Where sign matters, preserve zero and make the positive and negative directions interpretable.
For example, in a carbon-flux graph, define whether positive indicates emission to the atmosphere or removal from it. Different disciplines and measurement systems may use different sign conventions.
The sign convention must be recorded explicitly rather than inferred from a color choice.
6. Logarithmic scales
A logarithmic transformation is:
z = log_b(x)
where x must be positive for the conventional real-valued logarithm and b is a valid logarithm base greater than zero and not equal to one.
For base 10:
x = 1 log10(x) = 0
x = 10 log10(x) = 1
x = 100 log10(x) = 2
x = 1000 log10(x) = 3
Equal graphical distances represent equal multiplicative changes rather than equal arithmetic differences.
6.1 Suitable applications
Logarithmic axes can be useful for:
- Concentrations spanning orders of magnitude.
- Population sizes or frequencies with large dynamic ranges.
- Positive reaction rates.
- Certain exponential relationships.
- Other positive quantities where multiplicative differences are meaningful.
6.2 Unsuitable uses
Ordinary logarithmic axes cannot directly display zero or negative observations.
Do not silently remove, shift, or replace such values.
For example, adding an arbitrary constant before transformation changes the mathematical interpretation:
log10(x + c)
The value of c must be documented and scientifically justified.
6.3 Logarithmic axis versus logarithmic data transformation
Changing the display scale is distinct from replacing the underlying numerical variable with its logarithm.
Record whether the plotted values are original measurements shown on a logarithmic axis or transformed values plotted on a linear axis.
This distinction affects units, interpretation, captions, and numerical reconciliation.
7. Symmetric logarithmic scales
Some signed scientific quantities span several orders of magnitude in both positive and negative directions.
A symmetric logarithmic axis can compress large magnitudes while preserving both signs.
Such scales usually contain a linear region around zero and logarithmic behavior beyond a defined threshold.
Record:
- The exact transformation.
- The linear threshold around zero.
- The logarithm base.
- Tick positions and labels.
- The intended scientific interpretation.
A symmetric logarithmic axis is not equivalent to an ordinary linear axis and should not be presented without explanation when scale interpretation materially affects the conclusion.
8. Physical units and dimensional consistency
Measurement units are part of the scientific definition of a variable.
For example:
1000 milligrams = 1 gram
1000 grams = 1 kilogram
1000 kilograms = 1 metric tonne
Unit conversion must preserve the physical quantity represented.
8.1 Multiplicative conversions
Many unit conversions can be expressed as:
y = a*x
For example:
Mass in kilograms =
mass in grams / 1000
8.2 Affine conversions
Some conversions include an offset:
y = a*x + b
For temperature:
K = °C + 273.15
Absolute temperatures and temperature differences must be distinguished.
A change of 1 °C is a change of 1 K, but 0 °C is not 0 K.
8.3 Carbon and carbon dioxide quantities
Carbon mass and carbon dioxide mass are different quantities.
Using conventional molar masses:
Mass of CO2 =
mass of carbon * (44 / 12)
For example:
1 tonne C ≈ 3.667 tonnes CO2
This is a chemical mass conversion, not a carbon-removal verification method.
A figure should distinguish carbon stocks, carbon dioxide emissions, and verified carbon dioxide removal rather than treating them as interchangeable measures.
8.4 Rates, totals, and denominators
Always distinguish total quantities from rates.
For example:
tonnes CO2
tonnes CO2 per hectare
tonnes CO2 per hectare per year
These represent different physical dimensions.
Do not directly compare them on the same quantitative axis without a justified transformation and common measurement definition.
9. Uncertainty and unit conversion
Measurement uncertainty must be transformed consistently with the numerical quantity.
For an affine conversion:
y = a*x + b
an absolute standard uncertainty transforms as:
u_y = |a| * u_x
The offset b does not contribute uncertainty when it is an exact defined constant.
For example:
Measurement:
1000 ± 20 grams
Converted:
1.000 ± 0.020 kilograms
This relation assumes a known exact conversion factor and an appropriate uncertainty model.
Nonlinear transformations may require derivative-based propagation, Monte Carlo methods, or another justified approach.
Do not retain the numerical size of an uncertainty interval while changing the measurement units unless the conversion makes that correct.
10. Time and coordinate reference systems
Temporal and spatial axes require consistent reference definitions, not merely familiar labels.
10.1 Temporal axes
Document:
- Observation timestamps.
- Time zone or time standard.
- Reference period.
- Sampling frequency.
- Aggregation interval.
- Missing observations.
- Interpolation and resampling.
Irregularly spaced observations should not automatically be displayed as equally spaced categories when the actual temporal intervals matter.
10.2 Spatial coordinates
For maps and spatial visualizations, identify the coordinate reference system, units, spatial extent, and projection.
Latitude and longitude in degrees are not interchangeable with projected distances in meters.
A geographic axis may also need different aspect-ratio treatment from an ordinary numerical plot.
Projection choice and spatial distortion must be considered when the graphic supports claims about distance, direction, or area.
11. Construct a deterministic reference fixture
The following synthetic dataset demonstrates unit conversion and axis-scale validation.
| Record | Mass (g) | Mass (kg) |
|---|---|---|
| M01 | 500 | 0.5 |
| M02 | 1000 | 1.0 |
| M03 | 2000 | 2.0 |
| M04 | 4000 | 4.0 |
The values are synthetic and do not represent an actual measurement series.
Expected invariants:
mass_kg = mass_g / 1000
All converted masses are positive.
All converted values preserve the
relative ordering of the source values.
12. Generate reproducible axis comparisons
12.1 Prepare the environment
mkdir axis-scale-validation
cd axis-scale-validation
python3 -m venv .venv
source .venv/bin/activate
python -m pip install numpy matplotlib pytest
python --version
python -m pip freeze > requirements-lock.txt
For controlled research execution, retain exact dependency versions and a reviewed environment specification.
12.2 Create the reference script
Save as axis_scales.py.
from pathlib import Path
import hashlib
import json
import numpy as np
import matplotlib
matplotlib.use("Agg")
import matplotlib.pyplot as plt
OUTPUT = Path("axis-output")
OUTPUT.mkdir(exist_ok=True)
RECORD_IDS = (
"M01", "M02", "M03", "M04"
)
MASS_G = np.array(
[500., 1000., 2000., 4000.]
)
def sha256_file(path):
digest = hashlib.sha256()
with Path(path).open("rb") as handle:
for block in iter(
lambda: handle.read(1024 * 1024),
b""
):
digest.update(block)
return digest.hexdigest()
def grams_to_kilograms(values):
values = np.asarray(
values,
dtype=float
)
if not np.isfinite(values).all():
raise ValueError(
"Nonfinite mass values"
)
return values / 1000.0
def validate_axis(values, scale, limits):
values = np.asarray(
values,
dtype=float
)
if values.size == 0:
raise ValueError("Empty dataset")
if not np.isfinite(values).all():
raise ValueError("Nonfinite values")
lower, upper = limits
if not (
np.isfinite(lower)
and np.isfinite(upper)
and lower < upper
):
raise ValueError(
"Invalid axis limits"
)
if scale == "log":
if np.any(values <= 0):
raise ValueError(
"Log scale requires positive data"
)
if lower <= 0:
raise ValueError(
"Log limits must be positive"
)
elif scale != "linear":
raise ValueError(
"Unsupported scale"
)
if np.any(
(values < lower)
| (values > upper)
):
raise ValueError(
"Axis would clip source values"
)
return True
def create_reference_figures():
mass_kg = grams_to_kilograms(
MASS_G
)
expected = np.array(
[0.5, 1., 2., 4.]
)
np.testing.assert_allclose(
mass_kg,
expected,
rtol=0,
atol=1e-12
)
validate_axis(
mass_kg,
"linear",
(0, 4.5)
)
validate_axis(
mass_kg,
"log",
(0.1, 10)
)
paths = {}
for scale, limits in (
("linear", (0, 4.5)),
("log", (0.1, 10))
):
fig, ax = plt.subplots(
figsize=(7, 4.5),
dpi=160
)
ax.plot(
range(len(mass_kg)),
mass_kg,
marker="o"
)
ax.set_xticks(
range(len(RECORD_IDS)),
RECORD_IDS
)
ax.set_yscale(scale)
ax.set_ylim(*limits)
ax.set_xlabel(
"Synthetic record"
)
ax.set_ylabel(
"Mass (kg)"
)
ax.set_title(
f"{scale.capitalize()} axis"
)
fig.tight_layout()
path = OUTPUT / (
f"mass-{scale}.png"
)
fig.savefig(path)
plt.close(fig)
paths[scale] = path
return mass_kg, paths
if __name__ == "__main__":
mass_kg, paths = (
create_reference_figures()
)
report = {
"source_classification": "synthetic",
"record_ids": RECORD_IDS,
"source_unit": "g",
"display_unit": "kg",
"converted_values": (
mass_kg.tolist()
),
"axis_scales": [
"linear", "log"
],
"numerical_validation": "pass",
"visual_review": "not_tested",
"scientific_review": "not_tested",
"artifacts": {
scale: sha256_file(path)
for scale, path in paths.items()
}
}
(OUTPUT / "report.json").write_text(
json.dumps(report, indent=2),
encoding="utf-8"
)
print("Converted masses:", mass_kg)
print("Axis validation: PASS")
12.3 Execute the example
python axis_scales.py
Expected output:
Converted masses: [0.5 1. 2. 4. ]
Axis validation: PASS
Generated artifacts:
axis-output/
mass-linear.png
mass-log.png
report.json
The same numerical observations appear on linear and logarithmic axes.
The script uses record identifiers as the horizontal coordinates. The connecting line is a visual comparison and should not be interpreted as a physical trajectory or interpolated measurement.
The example validates conversion arithmetic and axis ranges. It does not certify the scientific appropriateness of either axis for an actual research question.
13. Test invalid scale and unit conditions
Automated tests should reject nonfinite measurements, invalid logarithmic domains, reversed limits, and unintended clipping.
Save as test_axis_scales.py.
import numpy as np
import pytest
from axis_scales import (
grams_to_kilograms,
validate_axis
)
def test_unit_conversion():
result = grams_to_kilograms(
[500., 1000., 2000.]
)
np.testing.assert_allclose(
result,
[0.5, 1., 2.],
rtol=0,
atol=1e-12
)
def test_valid_linear_scale():
assert validate_axis(
[-2., 0., 3.],
"linear",
(-3., 4.)
)
def test_valid_log_scale():
assert validate_axis(
[1., 10., 100.],
"log",
(0.1, 1000.)
)
def test_log_zero_rejected():
with pytest.raises(ValueError):
validate_axis(
[0., 1., 10.],
"log",
(0.1, 20.)
)
def test_log_negative_rejected():
with pytest.raises(ValueError):
validate_axis(
[-1., 1., 10.],
"log",
(0.1, 20.)
)
def test_reversed_limits_rejected():
with pytest.raises(ValueError):
validate_axis(
[1., 2., 3.],
"linear",
(4., 0.)
)
def test_clipping_rejected():
with pytest.raises(ValueError):
validate_axis(
[1., 2., 5.],
"linear",
(0., 4.)
)
@pytest.mark.parametrize(
"invalid",
[np.nan, np.inf, -np.inf]
)
def test_nonfinite_mass_rejected(invalid):
with pytest.raises(ValueError):
grams_to_kilograms(
[1000., invalid]
)
def test_unsupported_scale_rejected():
with pytest.raises(ValueError):
validate_axis(
[1., 2., 3.],
"unknown",
(0., 4.)
)
def test_empty_values_rejected():
with pytest.raises(ValueError):
validate_axis(
[],
"linear",
(0., 1.)
)
Execute:
python -m pytest -v test_axis_scales.py
The reference suite defines twelve test cases after expanding the parameterized nonfinite-value test.
These tests check numerical and configuration constraints. They do not replace visual review of axis labeling, accessibility, or the appropriateness of scale choices for a scientific question.
14. Validate graphical scaling independently
Automated tests should check both source values and the renderer’s numerical properties.
Relevant checks include:
- Axis scale type.
- Axis minimum and maximum.
- Tick labels and units.
- Data coordinate positions.
- Correct sign and ordering.
- Clipping and out-of-range observations.
- Color normalization where applicable.
- Export consistency.
For Matplotlib, the active y-axis scale can be inspected with:
assert ax.get_yscale() == "linear"
Or:
assert ax.get_yscale() == "log"
Such tests verify a renderer configuration. They do not establish that the chosen scale communicates the intended scientific meaning.
15. Accessible scales and numerical equivalents
Axis labels should remain understandable without relying solely on graphical inspection.
Provide:
- Full variable names and units.
- Clear descriptions of scale transformations.
- Accessible numerical tables.
- Descriptions of relevant comparisons.
- Explicit sign conventions.
- Appropriate tick labels.
- Readable precision and scientific notation.
- Non-color-only distinctions between plotted series.
For logarithmic axes, captions should state that equal visual spacing represents multiplicative rather than additive changes when that distinction is important to interpretation.
W3C guidance for complex images supports the use of extended descriptions and structured numerical information alongside graphics (W3C WAI, n.d.).
16. Scientific acceptance matrix
| Criterion | Pass condition | Evidence |
|---|---|---|
| Source identity | Correct source and revision identified | Dataset reference and provenance |
| Variable meaning | Scientific quantities correctly defined | Variable metadata |
| Unit consistency | All quantities use valid compatible units | Dimensional validation |
| Unit conversion | Converted values and uncertainties are correct | Independent calculations |
| Scale selection | Transformation justified by the scientific question | Method review |
| Axis range | Relevant values visible and context preserved | Limit checks |
| Baseline | Baseline appropriate to mark geometry and quantity | Graphical review |
| Sign preservation | Positive, zero, and negative semantics preserved | Numerical and graphical tests |
| Log domain | Transformation applied only to permitted values | Domain tests |
| Uncertainty | Uncertainty transformed and labeled correctly | Statistical review |
| Temporal reference | Time axes preserve intended timing | Temporal checks |
| Spatial reference | Coordinate units and projections appropriate | Geospatial validation |
| Accessibility | Quantities and transformations have accessible equivalents | Accessibility review |
| Reproducibility | Axis configuration and values can be reconstructed | Execution receipt |
| Scientific interpretation | Scale choices do not materially mislead the reader | Independent review |
Decision rule: Record each applicable criterion as Pass, Fail, or Not Tested. Passing conversion and domain tests is not sufficient to certify the scientific appropriateness of the resulting figure.
17. Reproducibility and provenance requirements
A research-quality figure should preserve enough information to reconstruct its scale and measurement semantics.
Archive:
- Source dataset identifier and immutable version.
- Original values and units.
- Converted values and conversion method.
- Uncertainty definitions and conversion rules.
- Scale type and transformation parameters.
- Axis limits and direction.
- Tick definitions and formatting.
- Missing-data handling and clipping policy.
- Temporal and spatial references where applicable.
- Rendering engine and dependency versions.
- Figure dimensions and exported artifacts.
- Source and output checksums.
- Executed tests and reviewer findings.
17.1 Illustrative axis manifest
{
"schema_version": "example-1.0",
"figure_id": "synthetic-mass-comparison",
"source": {
"dataset_id": "synthetic-mass",
"revision": "1.0",
"classification": "synthetic",
"sha256": null
},
"variable": {
"name": "mass",
"source_unit": "g",
"display_unit": "kg",
"conversion": "x / 1000"
},
"axis": {
"scale": "linear",
"lower": 0.0,
"upper": 4.5,
"unit": "kg",
"direction": "ascending"
},
"validation": {
"conversion": "not_tested",
"scale_domain": "not_tested",
"clipping": "not_tested",
"uncertainty": "not_tested",
"accessibility": "not_tested",
"scientific_review": "not_tested"
},
"publication_approval": "not_approved"
}
This is an illustrative documentation structure, not an implemented Sustainable Catalyst API contract.
Populate actual hashes, renderer versions, validation outcomes, and review decisions from executed workflows.
18. Sustainable Catalyst integration
Axis scales and units are relevant to several intended Sustainable Catalyst research workflows.
The following responsibilities are proposed rather than verified deployed capabilities.
| Application | Intended responsibility |
|---|---|
| Library | Preserve source variables, units, metadata, provenance, and versions |
| Workbench | Perform reproducible calculations and unit conversions where implemented |
| Research Lab | Validate measurement semantics, numerical methods, and uncertainty |
| Visualization & Graphing | Apply validated scales, axis formatting, and graphical encodings |
| Site Intelligence | Manage coordinate reference systems and spatial measurement contexts where supported |
| Decision Studio | Preserve unit consistency in scenario and model comparisons where implemented |
| Workspace | Track figure revisions, validation evidence, and review decisions |
| Research | Publish approved scientific figures with units, methods, and provenance |
18.1 Platform source audit
Before certifying Sustainable Catalyst axis-scale or unit-conversion functionality, identify:
- Owning repository and exact source revision.
- Implemented renderer and adapter versions.
- Source-variable and unit schemas.
- Actual unit-conversion implementation.
- Supported scale types and limitations.
- Clipping, zero, and negative-value behavior.
- Uncertainty conversion and propagation support.
- Runtime numerical and visual test evidence.
- Exported artifact inspection and accessibility results.
- Known defects and unsupported transformations.
The availability of an axis-scale option in a plotting library does not establish that unit semantics and scientific verification are enforced by the wider platform.
19. Scientific limitations and escalation
Escalate for scientific or engineering review when:
- Units are missing, ambiguous, or incompatible.
- A scale transformation changes the apparent meaning of the data.
- Positive or negative observations are concealed.
- A logarithmic scale silently excludes nonpositive measurements.
- Conversion factors or offsets are incorrect.
- Uncertainty values are inconsistent with the display unit.
- Spatial and temporal reference systems are mismatched.
- Axis ranges materially exaggerate or obscure the scientific relationship.
- Published findings depend on incorrect measurement semantics.
A scientifically appropriate axis cannot repair an invalid source dataset, biased experimental design, or incorrect model.
Measurement validity, unit consistency, numerical verification, graphical integrity, and scientific inference require separate review.
20. Technical references
- Bureau International des Poids et Mesures (BIPM) (2019, updated edition). The International System of Units (SI Brochure). Available at: BIPM SI Brochure.
- National Institute of Standards and Technology (NIST) (n.d.). Guide for the Use of the International System of Units (SI). Available at: NIST Special Publication 811.
- Matplotlib Development Team (n.d.). Axis scales. Available at: Matplotlib documentation.
- Matplotlib Development Team (n.d.). matplotlib.axes.Axes.set_yscale. Available at: Matplotlib API documentation.
- NumPy Developers (n.d.). numpy.testing.assert_allclose. Available at: NumPy documentation.
- Harris, C.R. et al. (2020). ‘Array programming with NumPy’, Nature, 585, pp. 357–362. Available at: https://doi.org/10.1038/s41586-020-2649-2.
- pytest Development Team (n.d.). pytest Documentation. Available at: https://docs.pytest.org/en/stable/.
- Vega-Lite Developers (n.d.). Scale. Available at: Vega-Lite documentation.
- W3C Web Accessibility Initiative (n.d.). Complex Images. Available at: W3C WAI guidance.
- World Wide Web Consortium (W3C) (2024). Web Content Accessibility Guidelines (WCAG) 2.2. Available at: https://www.w3.org/TR/WCAG22/.
21. Completion and verification record
| Field | Required record |
|---|---|
| Figure identifier | Figure and revision |
| Source artifact | Dataset version and integrity reference |
| Variable definition | Scientific quantity and dimensions |
| Unit consistency | Pass, Fail, or Not Tested |
| Unit conversion | Pass, Fail, or Not Tested |
| Scale appropriateness | Pass, Fail, or Not Tested |
| Axis range | Pass, Fail, or Not Tested |
| Sign preservation | Pass, Fail, or Not Tested |
| Uncertainty conversion | Pass, Fail, or Not Tested |
| Temporal/spatial reference | Pass, Fail, Not Tested, or Not Applicable |
| Renderer verification | Pass, Fail, or Not Tested |
| Accessibility | Pass, Fail, or Not Tested |
| Reproducibility | Pass, Fail, or Not Tested |
| Scientific review | Pass, Fail, or Not Tested |
| Reviewer | Actual reviewer and date |
| Evidence | Source data, calculations, scale specifications, figures, and test receipts |
| Outstanding limitations | Unresolved scientific or implementation issues |
Completion criterion: An axis scale and unit representation is accepted when the scientific quantity is correctly defined, unit conversions preserve the intended physical meaning, the selected scale and range support an accurate comparison, positive and negative values are handled appropriately, and applicable reproducibility, accessibility, and scientific review requirements are satisfied.
Scientific limitation: Correct axis scaling and unit representation improve transparency and reduce graphical distortion. They cannot establish the accuracy of source measurements, validate incorrect statistical models, or justify unsupported scientific inferences.
Current implementation status: Scientific methodology, unit-conversion rules, scale-selection principles, synthetic plotting examples, numerical tests, and proposed acceptance requirements documented. No particular Sustainable Catalyst axis-scale renderer, unit registry, or production integration is certified without actual source-code inspection, executed runtime testing, and release-specific acceptance evidence.
