Troubleshooting
Troubleshoot dimensional analysis — Sustainable Catalyst Workbench
Troubleshoot dimensional analysis — Sustainable Catalyst Workbench Availability: The physical-quantity implementation and the local examples below were inspected/tested at the pinned source revision. Full application startup, brow
Troubleshoot dimensional analysis — Sustainable Catalyst Workbench
Availability: The physical-quantity implementation and the local examples below were inspected/tested at the pinned source revision. Full application startup, browser controls, authentication, WordPress integration and deployed behavior remain UNVERIFIED. These are internal drafts, not approved public instructions. A local router test is not a production acceptance test.
The source module’s historical label is v11.7.0, but backend/app/release.py currently reports 14.0.0 and the README reports v10.4.0. Use the commit to identify this behavior; do not infer installed-version compatibility from those conflicting labels.
Start with the smallest reproducible case
Record the exact source/deployed revision, operation JSON, unit spellings, expected result and sanitized error. Preserve original measurements. The verified small case is 2 kg multiplied by 3 m/s²: the base result should be 6 kg·m/s², equivalent to 6 N. A second independent check is 36 km/h → 10 m/s. If these fail, diagnose the environment or request before interpreting a larger model.
Symptoms and documented behavior
| Symptom | Evidence-based explanation | Recovery |
|---|---|---|
No module named app.v10110 on normal backend test collection/startup |
Current app.main imports a module absent from the pinned source tree |
Have the maintainer reconcile the application source; do not claim the whole API is running. The how-to’s direct quantity-module exercise is a limited diagnostic, not a deployment workaround. |
| Version expected 11.7.0 but observed 14.0.0 | v1170 imports current APP_VERSION; upstream tests retain historical assertions |
Record both the commit and returned version; do not edit observations to satisfy the test. Release compatibility remains unresolved. |
| Invalid operation gives 422 locally | Pydantic enforces the operation enumeration | Use an operation from the developer reference; check request spelling. |
| Missing expression or operand gives an execution error | Fields are optional in the common model; operation-specific checks raise ValueError |
For conversion supply expression and targetUnit; for multiplication/addition supply left and right; for consistency supply nonempty operands. |
| Adding meters and seconds fails | Pint refuses addition of unlike dimensions | Re-examine the physical model. Convert only compatible units; multiplying or dividing is a different operation and requires a scientific reason. |
| Unknown unit gives an execution error | Pint cannot parse the supplied unit expression | Reduce to documented spellings such as meter, second, kilogram, newton; retain the original input and document any correction. |
compatible is true but magnitudes differ |
Compatibility compares dimensions, not physical equality | Convert to common units and compare magnitudes with a declared tolerance. |
| Force is displayed as compound SI units, not N | Serialization preserves/normalizes Pint unit representations | Compare the base magnitude and exponent map; request an explicit compatible conversion if needed. |
Client expects result.magnitude but receives a boolean |
compatible and consistency-check return booleans |
Branch on operation and validate the actual result shape. |
Missing fields, unknown units and incompatible addition were observed as HTTP 500 in the isolated router fixture with raise_server_exceptions=False. They are not a documented stable structured-error contract for every deployment. With the default local TestClient configuration, the original execution exception may be raised into the caller instead. Do not retry such requests indefinitely or infer a permissions problem from every 500.
Distinguish computational and scientific errors
A result of 18 kg·m²/s² for 2 kg × (3 m/s)² is mathematically correct. Calling it kinetic energy would be scientifically incorrect without the factor 1/2; kinetic energy under that model is 9 J. Similarly, a true dimensional-consistency flag does not validate coefficients, signs, boundary conditions or uncertainty. Correct the interpretation/model transparently, not the source data to obtain a desired answer.
The inspected module does not automatically propagate measurement uncertainty, prove arbitrary equations dimensionally homogeneous or certify significant figures. Negative or unexpected physical values require domain-specific interpretation; dimensional checks alone cannot reject every impossible model. No such additional validation is certified here.
Hashes, unavailable UI and escalation
If repeated requests give different fingerprints, compare complete payloads, software/Pint versions and version fields before assuming data corruption. Matching hashes in one fixed environment are a repeatability check, not proof of scientific validity or guaranteed cross-version equivalence.
No browser controls, screenshots or deployed authentication flow were verified. The optional WordPress adapter’s source reports an unavailable backend when its shared request helper is missing; this audit did not install it or test its proxy/error rendering. Escalate with a sanitized source-linked reproducer and separate expected versus observed behavior. Include the known full-app startup and release-drift gaps; leave the affected workflow unverified until repaired and retested.
Evidence and related reading
Physical-quantity request models, operations, result serialization and routes; Existing quantity tests; Canonical source release identity.
Verification on 2026-11-10: 23 focused local assertions passed against the actual quantity router in a minimal FastAPI application. Six existing upstream test functions passed in that isolated router context; the status test failed because it expects 11.7.0 rather than the returned 14.0.0. The normal upstream suite could not collect because full app.main imports missing app.v10110. Static tests: three passed, two failed on old release/image expectations. These failures were recorded, not patched away. No deployed endpoint, UI, permission or scientific peer-review acceptance was performed.
Related: overview, worked how-to, research protocol, developer reference, troubleshooting. Technical/scientific review owner remains unassigned; publication remains blocked.